Appendix B
363
Key Definitions
Softkeys displayed by pressing the [Meas] key
B.
Ke
y De
fin
iti
on
s
Softkeys displayed by pressing the
[Meas]
key
Table B-7
Measurement parameter (Measurement) menu (1/3)
Key operation:
[Meas]
Softkey
Function
GPIB command
|Z| -
q
|
Selects impedance absolute value and impedance phase as measurement
parameters. The 1st parameter on the softkey label (in this case, |Z|) is assigned
to trace A; the 2nd parameter (in this case,
q
), to trace B. (This system of trace
assignent is applicable to other measurement parameters.)
MEAS IMPH
R - X
|
Selects series resistance and reactance as measurement parameters.
MEAS IRIM
Ls - Rs
|
Selects series inductance and series resistance as measurement parameters.
MEAS LSR
Ls - Q
|
Selects series inductance and Q factor (quality factor) as measurement
parameters.
MEAS LSQ
Cs - Rs
|
Selects series capacitance and series resistance as measurement parameters.
MEAS CSR
Cs - Q
|
Selects series capacitance and Q factor (quality factor) as measurement
parameters.
MEAS CSQ
Cs - D
Selects series capacitance and dissipation factor as measurement parameters.
MEAS CSD
more 1/3
Displays Table B-8, “Measurement parameter (Measurement) menu (2/3),” on
page 363.
(N/A)
Table B-8
Measurement parameter (Measurement) menu (2/3)
Key operation:
[Meas] - more 1/3
Softkey
Function
GPIB command
|Y| -
q
|
Selects admittance absolute value and admittance phase as measurement
parameters.
MEAS AMPH
G - B
|
Selects conductance and susceptance as measurement parameters.
MEAS ARIM
Lp - G
|
Selects parallel inductance and conductance as measurement parameters.
MEAS LPG
Lp - Q
|
Selects parallel inductance and Q factor (quality factor) as measurement
parameters.
MEAS LPQ
Cp - G
|
Selects parallel capacitance and conductance as measurement parameters.
MEAS CPG
Cp - Q
|
Selects parallel capacitance and Q factor (quality factor) as measurement
parameters.
MEAS CPQ
Cp - D
Selects parallel capacitance and dissipation factor as measurement parameters.
MEAS CPD
more 2/3
Displays Table B-9, “Measurement parameter (Measurement) menu (3/3),” on
page 364.
(N/A)
Содержание 4294A
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...8 ...
Страница 30: ...22 Chapter1 Installation Power Cable Figure 1 2 Alternative Power Cable Options ...
Страница 70: ...62 Chapter3 Front Rear Panel and LCD Display Items Displayed on the LCD ...
Страница 100: ...92 Chapter5 Setting Measurement Conditions Setting Sweep Range Figure 5 7 After MKR CENTER Figure 5 8 ...
Страница 101: ...Chapter 5 93 Setting Measurement Conditions Setting Sweep Range 5 Setting Measurement Conditions Figure 5 9 ...
Страница 106: ...98 Chapter5 Setting Measurement Conditions Setting Number of Points NOP Figure 5 13 Number of points 801 ...
Страница 330: ...322 Chapter9 Setting Using Control and Management Functions Performing Self Diagnosis of the Agilent 4294A ...
Страница 436: ...428 AppendixB Key Definitions Softkeys displayed by pressing the Recall key ...
Страница 454: ...446 AppendixC Error messages WRONG I O PORT DIRECTION ...
Страница 462: ...454 AppendixD Initial Settings Initial Settings Settings that can be Saved Recalled Settings that can be Backed Up ...
Страница 468: ......