Appendix B
373
Key Definitions
Softkeys displayed by pressing the [Scale Ref] key
B.
Ke
y De
fin
iti
on
s
Softkeys displayed by pressing the
[Scale Ref]
key
Table B-27
Scale reference (Scale Ref) menu (1-1/2)
Key operation:
[Scale Ref]
1
1. When the measurement parameter is not COMPLEX Z-Y and the vertical axis is in the linear or percentage format.
Softkey
Function
GPIB command
AUTO SCALE
For the selected trace (data trace/memory trace of trace A/B), executes automatic
scale adjustment based on the trace data when the key is pressed. The trace is
magnified and displayed so that the graph contains the entire data, allowing you
to easily grasp the overall characteristics. You can select the data trace or the
memory trace with the SCALE FOR [ ] key in Table B-28, “Scale reference
(Scale Ref) menu (1-2/2),” on page 373.
AUTO
SCALE/DIV
For the selected trace (data trace/memory trace of trace A/B), sets a value for the
scale per division in the axis for measured value. This is one of the scale
configurations using REFERENCE POSITION, REFERENCE VALUE, and
SCALE/DIV.
SCAL <value>
REFERENCE POSITION
For the selected trace (data trace/memory trace of trace A/B), sets the position of
the scale reference line. The position of the reference line is indicated by a value,
assuming that the lowest line of the graph is 0 and the highest line is 10. This is
one of the scale configurations using REFERENCE POSITION, REFERENCE
VALUE, and SCALE/DIV.
REFP <value>
REFERENCE VALUE
For the selected trace (data trace/memory trace of trace A/B), sets a reference
value (the value of the scale reference line). This is one of the scale
configurations using REFERENCE POSITION, REFERENCE VALUE, and
SCALE/DIV.
REFV <value>
MKR
®
REFERENCE
For the selected trace (data trace/memory trace of trace A/B), substitutes the
absolute value of the main marker into the reference value (the value of the scale
reference line) regardless of the value of the
D
marker. As a result, the marker
moves to the reference line position.
MKRREF
TOP VALUE
Sets a value of the top line in the scale graph. This is one of the scale
configurations using TOP VALUE and BOTTOM VALUE.
TOPV <value>
BOTTOM VALUE
Sets a value of the bottom line in the scale graph. This is one of the scale
configurations using TOP VALUE and BOTTOM VALUE.
BOTV <value>
more 1/2
Displays Table B-28, “Scale reference (Scale Ref) menu (1-2/2),” on page 373.
(N/A)
Table B-28
Scale reference (Scale Ref) menu (1-2/2)
Key operation:
[Scale Ref] - more1/2
Softkey
Function
GPIB command
SCALE FOR [ ]
When both the data trace and the memory trace are displayed on the screen,
selects the kind of trace to which the scale configurations in Table B-27, “Scale
reference (Scale Ref) menu (1-1/2),” on page 373 are applied from the data trace
[DATA] or the memory trace [MEMO].
SCAF {DATA|MEMO}
D&M COUPLE ON off
When both the data trace and the memory trace are displayed on the screen,
selects performing the scale configurations in Table B-27, “Scale reference
(Scale Ref) menu (1-1/2),” on page 373 for both the data trace and the memory
trace together (couple on) or for each of them separately (couple off).
SCAC {ON|OFF}
Содержание 4294A
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...8 ...
Страница 30: ...22 Chapter1 Installation Power Cable Figure 1 2 Alternative Power Cable Options ...
Страница 70: ...62 Chapter3 Front Rear Panel and LCD Display Items Displayed on the LCD ...
Страница 100: ...92 Chapter5 Setting Measurement Conditions Setting Sweep Range Figure 5 7 After MKR CENTER Figure 5 8 ...
Страница 101: ...Chapter 5 93 Setting Measurement Conditions Setting Sweep Range 5 Setting Measurement Conditions Figure 5 9 ...
Страница 106: ...98 Chapter5 Setting Measurement Conditions Setting Number of Points NOP Figure 5 13 Number of points 801 ...
Страница 330: ...322 Chapter9 Setting Using Control and Management Functions Performing Self Diagnosis of the Agilent 4294A ...
Страница 436: ...428 AppendixB Key Definitions Softkeys displayed by pressing the Recall key ...
Страница 454: ...446 AppendixC Error messages WRONG I O PORT DIRECTION ...
Страница 462: ...454 AppendixD Initial Settings Initial Settings Settings that can be Saved Recalled Settings that can be Backed Up ...
Страница 468: ......