Chapter 8
215
Analysis and Processing of Result
Listing data at several points on the trace
8. A
nal
ys
is
a
nd P
roc
es
si
ng
of
Res
ult
Figure 8-2
Displaying the marker positions using the softkey labels of the sub-markers
Listing the marker positions with the marker list function
The marker position display provided by the softkey labels in the Sub-Marker Setting
menu may not be usable if you want to show the display at all times because the softkey
display changes depending on the keys you operate. In this case, you can use the marker
list function.
After performing the steps in“Displaying several marker positions using softkey labels” on
page 214, follow these steps:
Step 1.
Press the
[Utility]
key to display the Utility menu.
Step 2.
Press the
MKR LIST
on
OFF
key to turn on the marker list function. When the marker list
function is turned on, the measured graph is displayed in the upper half of the screen and
the positions of all the markers on the trace are listed in the lower half of the screen.
Softkey label
State of marker list function
MKR LIST ON off
On (the positions of the markers on the trace are listed
in the lower half of the screen)
MKR LIST on OFF
Off
Содержание 4294A
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...8 ...
Страница 30: ...22 Chapter1 Installation Power Cable Figure 1 2 Alternative Power Cable Options ...
Страница 70: ...62 Chapter3 Front Rear Panel and LCD Display Items Displayed on the LCD ...
Страница 100: ...92 Chapter5 Setting Measurement Conditions Setting Sweep Range Figure 5 7 After MKR CENTER Figure 5 8 ...
Страница 101: ...Chapter 5 93 Setting Measurement Conditions Setting Sweep Range 5 Setting Measurement Conditions Figure 5 9 ...
Страница 106: ...98 Chapter5 Setting Measurement Conditions Setting Number of Points NOP Figure 5 13 Number of points 801 ...
Страница 330: ...322 Chapter9 Setting Using Control and Management Functions Performing Self Diagnosis of the Agilent 4294A ...
Страница 436: ...428 AppendixB Key Definitions Softkeys displayed by pressing the Recall key ...
Страница 454: ...446 AppendixC Error messages WRONG I O PORT DIRECTION ...
Страница 462: ...454 AppendixD Initial Settings Initial Settings Settings that can be Saved Recalled Settings that can be Backed Up ...
Страница 468: ......