Chapter 10
327
Specifications and Supplemental Performance Characteristics
Basic Characteristics
10.
Sp
ec
ifi
ca
tio
ns
and
S
upp
le
men
tal Per
fo
rm
anc
e
C
har
ac
ter
isti
cs
NOTE
Vmon
: dc voltage bias monitor reading value [mV]
Imon
: dc current bias monitor reading value [mA]
Zd
= 0.3 (at four-terminal pair port of the 4294A, adapter setup: NONE)
Zd
= 2.0 (at 3.5 mm port of the 42941A, adapter setup: 42941A Impedance Probe)
Zd
= 0.5 (at 7-mm port of the 42942A, adapter setup: 42942A Terminal Adapter)
Zd
= 1.0 (at measurement port of the 16048G, adapter setup: four-terminal pair 1m)
Zd
= 1.5 (at measurement port of the 16048H, adapter setup: four-terminal pair 2m)
Range
0 to
±
40 V (see Figure 10-1)
Resolution
1 mV
Accuracy
±
[0.5% + (5 +
Z
d
´
|
I
mon
|) mV]
(at 23
±
5
°
C, typical)
±
[1.0% + (10 +
Z
d
´
|
I
mon
|) mV]
(beyond 23
±
5
°
C, typical)
dc current bias at constant
current mode
Range
0 to
±
100 mA (see Figure 10-1)
Resolution
40
m
A
Accuracy
±
[1% + (0.5 + |
V
mon
|/10000) mA]
(at 23
±
5
°
C, typical)
±
[2% + (1.0 + |
V
mon
|/5000) mA]
(beyond 23 ± 5
°
C, typical)
dc bias monitor
dc voltage range
(same as the dc voltage bias setting range)
dc voltage accuracy
±
[0.2% + (5 +
Z
d
´
|
I
mon
|) mV] (at 23
±
5
°
C)
±
[0.4% + (10 +
Z
d
´
|
I
mon
|) mV] (beyond 23
±
5
°
C)
dc current range
(Same as the dc current bias setting range)
dc current monitor
accuracy
±
[1% + (0.5 + |
V
mon
|/10000) mA] (at 23
±
5
°
C)
±
[2% + (1.0 + |
V
mon
|/5000) mA] (beyond 23
±
5
°
C)
Output impedance
25
W
(nominal)
Содержание 4294A
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...8 ...
Страница 30: ...22 Chapter1 Installation Power Cable Figure 1 2 Alternative Power Cable Options ...
Страница 70: ...62 Chapter3 Front Rear Panel and LCD Display Items Displayed on the LCD ...
Страница 100: ...92 Chapter5 Setting Measurement Conditions Setting Sweep Range Figure 5 7 After MKR CENTER Figure 5 8 ...
Страница 101: ...Chapter 5 93 Setting Measurement Conditions Setting Sweep Range 5 Setting Measurement Conditions Figure 5 9 ...
Страница 106: ...98 Chapter5 Setting Measurement Conditions Setting Number of Points NOP Figure 5 13 Number of points 801 ...
Страница 330: ...322 Chapter9 Setting Using Control and Management Functions Performing Self Diagnosis of the Agilent 4294A ...
Страница 436: ...428 AppendixB Key Definitions Softkeys displayed by pressing the Recall key ...
Страница 454: ...446 AppendixC Error messages WRONG I O PORT DIRECTION ...
Страница 462: ...454 AppendixD Initial Settings Initial Settings Settings that can be Saved Recalled Settings that can be Backed Up ...
Страница 468: ......