412
Appendix B
Key Definitions
Softkeys displayed by pressing the [System] key
Table B-87
List deletion (Clear List?) menu
Key operation:
[System] - LIMIT TEST - EDIT LIMIT LINE - CLEAR LIST
Softkey
Function
GPIB command
yes
Deletes the contents of the limit line table that is being edited from the edit area.
Even after using this key, you can keep the table without deleting it by pressing
the cancel key in Table B-83, “Limit line edit (Edit Limit) menu,” on page 409,
which is stored in original form before the limit line table edit mode is invoked.
(N/A)
cancel
Cancels deletion of the contents of the limit line table being edited from the edit
screen. The tables that have already been edited are kept in the edit area.
(N/A)
Table B-88
Limit line offset (Limit Offset) menu
Key operation:
[System] - LIMIT TEST - LIMIT LINE OFFSETS
Softkey
Function
GPIB command
SWP PARAM OFFSET
For the limit lines currently set in the limit line table, sets the sweep parameter
offset value. By setting the sweep parameter offset value, all of the set limit lines
are moved in the sweep parameter direction by the offset value.
LIMIPRMO <value>
AMPLITUDE OFFSET
For the limit lines currently set in the limit line table, sets the amplitude offset
value. By setting the amplitude offset value, all of the set limit lines are moved in
the measurement parameter direction by the offset value.
LIMIAMPO <value>
MKR
®
AMP. OFST.
Substitutes the measurement parameter value at the main marker on the current
active trace (A or B) into the amplitude offset value. If you have set the limit
center value in the limit line table to zero, you can use this key to change the
limit lines using the measurement parameter value at the main marker position as
the limit center value. Therefore, you can use this key to maintain a constant
limit line shape and difference value (difference between the upper and lower
limits) in order to change only the center value for each DUT, that is, to define
limit lines immediately suitable for the DUT .
MKRAMPO
return
Returns to Table B-82, “Limit test (Limit Test) menu,” on page 408.
(N/A)
Table B-89
Internal clock (Clock) menu
Key operation:
[System] - CLOCK
Softkey
Function
GPIB command
TIME
ä
Displays Table B-90, “Time configuration (Set Time) menu,” on page 413.
SETCTIME
<hour>,<minute>,<seco
nd>
DATE
ä
Displays Table B-91, “Date configuration (Set Date) menu,” on page 413.
SETCDATE
<year>,<month>,<day>
DATE MODE [ ]
Toggles the date display format between “2-digit number representing
month/2-digit number representing day/2-digit number representing year”
[MM/DD/YY] and “2-digit number representing day/2-digit number
representing month/2-digit number representing year” [DD/MM/YY]. This
display format is applied only to time stamps when outputting to a printer (TIME
on OFF key in Table B-100, “Copy configuration (Copy Setup) menu (2/2),” on
page 418).
DMODE {MDY|DMY}
return
Returns to Table B-74, “System (System) menu,” on page 404.
(N/A)
Содержание 4294A
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...8 ...
Страница 30: ...22 Chapter1 Installation Power Cable Figure 1 2 Alternative Power Cable Options ...
Страница 70: ...62 Chapter3 Front Rear Panel and LCD Display Items Displayed on the LCD ...
Страница 100: ...92 Chapter5 Setting Measurement Conditions Setting Sweep Range Figure 5 7 After MKR CENTER Figure 5 8 ...
Страница 101: ...Chapter 5 93 Setting Measurement Conditions Setting Sweep Range 5 Setting Measurement Conditions Figure 5 9 ...
Страница 106: ...98 Chapter5 Setting Measurement Conditions Setting Number of Points NOP Figure 5 13 Number of points 801 ...
Страница 330: ...322 Chapter9 Setting Using Control and Management Functions Performing Self Diagnosis of the Agilent 4294A ...
Страница 436: ...428 AppendixB Key Definitions Softkeys displayed by pressing the Recall key ...
Страница 454: ...446 AppendixC Error messages WRONG I O PORT DIRECTION ...
Страница 462: ...454 AppendixD Initial Settings Initial Settings Settings that can be Saved Recalled Settings that can be Backed Up ...
Страница 468: ......