Appendix B
365
Key Definitions
Softkeys displayed by pressing the [Format] key
B.
Ke
y De
fin
iti
on
s
Softkeys displayed by pressing the
[Format]
key
Table B-11
Format (Format) menu (1)
Key operation:
[Format]
1
1. When the measurement parameter is not COMPLEX Z-Y.
Softkey
Function
GPIB command
LIN
|
Selects the linear scale as the vertical axis (Y axis) for the graph.
FMT LINY
LOG
Selects the log (logarithm) scale as the vertical axis (Y axis) for the graph.
FMT LOGY
PHASE UNIT [ ]
Toggles the phase display unit between degree [DEG] and radian [RAD] each
time this key is pressed.
PHAU {DEG|RAD}
EXP PHASE on OFF
Toggles on and off the phase expansion display function each time this key is
pressed. ON off in the softkey label indicates ON state; on OFF, OFF state.
EXPP {ON|OFF}
Table B-12
Format (Format) menu (2)
Key operation:
[Format]
1
1. When the measurement parameter is COMPLEX Z-Y. (Key operation: [Meas] - more 1/3 - more 2/3 - COMPLEX Z-Y)
Softkey
Function
GPIB command
COMPLEX
|
Selects the complex plane to display the graph. This plane has a grid scale whose
horizontal axis is the actual axis and whose vertical axis is an imaginary axis.
FMT COMP
POLAR
Selects the polar coordinates to display the graph. Complex parameters are
displayed in an absolute value scale (distance from the origin) and a phase scale
(counterclockwise phase angle).
FMT POLA
PHASE UNIT [ ]
Toggles the phase display unit between degree [DEG] and radian [RAD] each
time this key is pressed.
PHAU {DEG|RAD}
EXP PHASE on OFF
Toggles on and off the phase expansion display function each time this key is
pressed. ON off in the softkey label indicates ON state; on OFF, OFF state.
EXPP {ON|OFF}
Содержание 4294A
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 16: ...8 ...
Страница 30: ...22 Chapter1 Installation Power Cable Figure 1 2 Alternative Power Cable Options ...
Страница 70: ...62 Chapter3 Front Rear Panel and LCD Display Items Displayed on the LCD ...
Страница 100: ...92 Chapter5 Setting Measurement Conditions Setting Sweep Range Figure 5 7 After MKR CENTER Figure 5 8 ...
Страница 101: ...Chapter 5 93 Setting Measurement Conditions Setting Sweep Range 5 Setting Measurement Conditions Figure 5 9 ...
Страница 106: ...98 Chapter5 Setting Measurement Conditions Setting Number of Points NOP Figure 5 13 Number of points 801 ...
Страница 330: ...322 Chapter9 Setting Using Control and Management Functions Performing Self Diagnosis of the Agilent 4294A ...
Страница 436: ...428 AppendixB Key Definitions Softkeys displayed by pressing the Recall key ...
Страница 454: ...446 AppendixC Error messages WRONG I O PORT DIRECTION ...
Страница 462: ...454 AppendixD Initial Settings Initial Settings Settings that can be Saved Recalled Settings that can be Backed Up ...
Страница 468: ......