background image

Pulse™ Series Remote 

Monitoring Systems 

Operations Manual

 

Document #701009 

 

Version 1.0 

Содержание Pulse Series

Страница 1: ...Pulse Series Remote Monitoring Systems Operations Manual Document 701009 Version 1 0...

Страница 2: ......

Страница 3: ...our personnel to become familiar with the system s equipment and its operation The secondary function of this manual is to serve as a training guide consequently you will find more equipment and proce...

Страница 4: ...Pulse 24 Viewing Graphs on Pulse Unit 26 Viewing Daily Graph 26 Viewing Monthly Graph 27 Querying Data on Pulse Unit 28 Viewing Log Files 31 Sending a RemoteCall 35 Making Changes to Your Pulse 36 Tur...

Страница 5: ...3 Appendix A 47 Appendix B 48...

Страница 6: ...ta out on the production floor that can be viewed via the web anywhere in the world or as close as your office About this Guide This guide describes how to setup the system the basic features of your...

Страница 7: ...ore the system can start running When configuring the Ethernet and Email settings an IT technician will be required Hardware Setup The hardware setup is easy to configure Supply power to the unit Setu...

Страница 8: ...tware Setup To enter the configuration setup for the Pulse unit press the toolbox button This should bring up the Configuration Screen You should configure the system in this order Ethernet Sensors Em...

Страница 9: ...ess Subnet and Gateway for your Pulse unit Your IT Technician should provide with you with this information Simply click on the screen and use the keypad to enter the information Click the button afte...

Страница 10: ...8 Sensors Setup You need to configure the Sensors that you plugged into the unit by pressing the button on the Configuration Screen...

Страница 11: ...uld like the counts to be shown on the Pulse Unit toggle the Show option to Yes If you would like hourly counts to be permanently logged to a log file the Log button needs to be toggled to Yes This da...

Страница 12: ...dvanced Sensor Setup For example suppose you are measuring a box of cereal If you have the Type field set to Normally Closed the On field will be how long the box of cereal will be in front of the sen...

Страница 13: ...of the Sensor Name If you use the network to view the report then the sensor name will be grayed out The Type option allows you to set the sensor to Normally Open N O or Normally Closed N C This optio...

Страница 14: ...12 Email Setup Press the button on the Main Configuration Screen This is where you need to setup all email information for the Pulse unit...

Страница 15: ...u with this information Note You can change the default email address that will be used when emails are sent Just click the box in the middle of the screen and use the keypad to enter the new email ad...

Страница 16: ...and use the keypad to enter the address You have the option of turning off these emails by toggling the buttons to No Press the Back button when finished Note You have the option of turning off these...

Страница 17: ...he option of turning these emails on and off by toggling the buttons to Yes or No Press the Back button when finished Once all email addresses have been entered press the Save all Email Settings butto...

Страница 18: ...System Setup Press the button on the Main Configuration Screen You will be taken to the System Configuration screen This is where you need to setup the date time and administrator password for your un...

Страница 19: ...nter a four 4 digit number password Default password is 0000 Note You can Calibrate the Touch screen functionality by pressing the Calibrate Touch button Use your finger or a stylus and follow the sim...

Страница 20: ...18 Setup Complete Everything should be ready to go You should now have a working Pulse Press the button to access the Main Pulse Screen...

Страница 21: ...Viewing Count Details Viewing count details for each sensor is very simple Just look at the Pulse unit The Main Pulse Screen shows the counts for each sensor installed It shows totals for the current...

Страница 22: ...t in your web browser and you can view Daily Weekly and Monthly data for each sensor Note If the sensor name is grayed out then there has not been any production for the period of time specified on th...

Страница 23: ...Line This will take you to the Details Screen for that sensor which will show counts for the current hour current day current week current month current shift and the Call Count The Call Count is how...

Страница 24: ...s visible then the sensor is on If the black circle is showing then the Sensor is off If the white circle is showing then the Sensor is off Note Call Count will be reset at 12 00 am every night Note S...

Страница 25: ...keys to enter the password and then press 3 System Button Access System Configuration Screen 4 Reset Daily Button Reset Daily Totals shown on Details Screen and related emails 5 Reset Weekly Button R...

Страница 26: ...Pulse Daily Emails to inform the recipient of the totals for the day Weekly Emails to inform the recipient of the totals for the week Monthly Emails to inform the recipient of the totals for the month...

Страница 27: ...thly Totals emails are sent at midnight They will give the totals for each sensor installed on the Pulse unit Note The recipient of these emails can be changed at any time Please see Changing Email Ad...

Страница 28: ...count for the 24 hours of the day It also shows the Best Hour of the day You can use the scroll buttons to see the specific numbers for each hour This display restarts at 12 00 am Press To 1 Sensor Di...

Страница 29: ...month It also shows the Best Day of the month You can use the scroll buttons to see the specific numbers for each day This display restarts at 12 00 am on the 1st of the each month Press To 1 Sensor...

Страница 30: ...est Daily Total Best Hourly Total Hours Up and Hours Down This screen also shows the Average Parts Per Hour for Up Time First Day and All Time Note Hours Up is the number of hours for the time input t...

Страница 31: ...View Query Screen 3 Month Display Box Use Keypad to Choose Month 4 Start Day Box Use Keypad to choose Start Day for Query 5 End Day Box Use Keypad to choose End Day for Query 6 Start Hour Box Use Keyp...

Страница 32: ...30 The Query results can be emailed to the address setup in the Email Configuration Screen by pressing the button...

Страница 33: ...ownload this program directly from the Siemens website or from a link on the Accurate Logic website www accuratelogic com Once you have the program click to install Follow the online instructions Once...

Страница 34: ...32 Click the New Address button and type in the IP Address of the Pulse Unit and a description then click the Save button Click the OK button when finished...

Страница 35: ...t IP Address should now be listed Double click the IP Address Then double click 256k Memory Cartridge This will bring up the sensors installed on the Pulse Unit Double click the sensor you want to see...

Страница 36: ...a file is broken up by day and hours This data file will show all of the data the sensor has collected since it was installed This file can hold three 3 years of data and will start rewriting from the...

Страница 37: ...ess that was setup in the RemoteCall Email Configuration Screen This email will be sent immediately and notify the recipient of which sensor is having a problem To send a RemoteCall the operator just...

Страница 38: ...tion Button Access Password Screen 2 Password Box Use keypad keys to enter the password and then press 3 Sensors Button Access Sensor Configuration Screen 4 Show button Toggle On Off Counts Display on...

Страница 39: ...Button Access Password Screen 2 Password Box Use keypad keys to enter the password and then press 3 Sensors Button Access Sensor Configuration Screen 4 Name Display Box you wish to change Use keypad...

Страница 40: ...the email addresses of where the daily weekly monthly and query reports get sent Press To 1 Toolbox Button Access Password Screen 2 Password Box Use keypad keys to enter the password and then press 3...

Страница 41: ...he emergency emails when the Remote Call buttons are pressed on the Pulse unit Press To 1 Toolbox Button Access Password Screen 2 Password Box Use keypad keys to enter the password and then press 3 Em...

Страница 42: ...changed Press To 1 Toolbox Button Access Password Screen 2 Password Box Use keypad keys to enter the password and then press 3 Email Button Access Email Configuration Screen 4 Email Label Data Box Use...

Страница 43: ...of the Pulse unit Press To 1 Toolbox Button Access Password Screen 2 Password Box Use keypad keys to enter the password and then press 3 System Button Access System Configuration Screen 4 Keypad Keys...

Страница 44: ...ord Box Use keypad keys to enter the password and then press 3 System Button Access System Configuration Screen 4 Administrator Password Data Box Enter New Password 4 numerical Changing Screen Contras...

Страница 45: ...5 Contrast Decrease Change color contrast of the screen Changing Ethernet Information You can change the IP Address Subnet and Gateway information Press To 1 Toolbox Button Access Password Screen 2 Pa...

Страница 46: ...44 Press To 4 Data Boxes Change information 5 Save Button Save New Ethernet Information...

Страница 47: ...g this boot up time Web page not showing data If the Pulse unit has been turned off for an extended period of time the pulse s internal web data will need to be reloaded Press the button on the System...

Страница 48: ...figure Sensors screen Please follow instructions for Sensor Setup under Setting up the System section If your Pulse is having problems click the warning button on the main screen This will give furthe...

Страница 49: ...A 4 Wire NPN Sensor Hookup Sensor with RemoteCall Box ACC SPLT M12 ACC SPLT M12 ACC CBL4 10 4 Wire 10 Foot ACC CBL4 25 4 Wire 25 Foot ACC CBL4 50 4 Wire 50 Foot RemoteCall 3 Wire NPN Sensor Hookup AC...

Страница 50: ...48 Appendix B Common 0 VDC RemoteCall Signal Supply 24 VDC Sensor Signal PIN 2 PIN 4 PIN 1 Pulse M12 Sensor Connector Pinout Brown White Blue Black PIN 3...

Отзывы: