4.1 SERVOPACK Ratings and Specifications
4-3
4
4.1 SERVOPACK Ratings and Specifications
4.1.1 Single-phase 100 V
The value of the input power supply voltage is maximum 127 Vrms.
4.1.2 Single-phase/Three-phase 200 V
The value of the input power supply voltage is maximum 253 Vrms.
• Take appropriate measures to ensure that the input power supply is supplied within the specified voltage
range.
An incorrect input power supply may result in damage to the SERVOPACK. If the voltage exceeds these values, use
a step-down transformer so that the voltage will be within the specified range.
CAUTION
SERVOPACK Model SGDH-
A3B
A5B
01B
02B
Max. Applicable Servomotor
Capacity (kW)
0.03
0.05
0.1
0.2
Continuous Output Current
(Arms)
0.66
0.95
2.4
3.0
Max. Output Current (Arms)
2.0
2.9
7.2
9.0
Input Power
Supply
Main Circuit
Single-phase 100 to115 VAC
+
10 to -15
%,
50/60 Hz
Control Circuit
Single-phase 100 to115 VAC
+
10 to -15
%
, 50/60 Hz
Configuration
Base-mounted (Rack mounting available as an option)
Regenerative Processing
External regenerative resistor
SERVOPACK
Model SGDH-
A3A A5A 01A 02A 04A 05A 08A 10A 15A 20A 30A 50A 60A 75A 1AA 1EA
Max. Applicable
Servomotor
Capacity (kW)
0.03 0.05
0.1
0.2
0.4
0.45 0.75
1.0
1.5
2.0
3.0
5.0
6.0
7.5
11
15
Continuous Out-
put Current
(Arms)
0.44 0.64 0.91
2.1
2.8
3.8
5.7
7.6
11.6 18.5 24.8 32.9 46.9 54.7 58.6 78.0
Max. Output Cur-
rent (Arms)
1.3
2.0
2.8
6.5
8.5
11.0 13.9
17
28
42
56
84
110
130
140
170
Input
Power
Supply
Main
Circuit
Single-phase/Three-phase 200 to 230 VAC
+
10 to -15
%
, 50/60 Hz
Control
Circuit
Single-phase 200 to 230 VAC
+
10 to -15
%
, 50/60 Hz
Configuration
Base-mounted (Rack mounting available as an option)
Base-mounted (Duct-
ventilated available as an
option)
Regenerative
Processing
External regenerative resistor
Built-in
External regenerative
resistor
Summary of Contents for SGDH
Page 435: ...8 3 8...