5.2 Servomotor Main Circuit Wire Size and Connectors
5-23
5
(3) 200 V and 400 V Servomotors With Holding Brakes
The three-phase 200 V 5.5 to 15.0 kW and three-phase 400 V 0.45 to 15.0 kW servomotors require (a) servomo-
tor-end connector and (b) brake power supply connector.
The straight plug type JA06A-24-10S-J1-EB and L-shaped plug type JA08A-24-10S-J1-EB conform to IP67 Protective
Construction Standard only.
(a) Servomotor-end Connector
i) 200 V 0.45 to 4.4 kW
INFO
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Applicable Cable
Range in mm (in)
(For reference)
Straight
L-shaped
0.45
0.85
1.3
JL04V-2E20-15PE-B
JL04V-6A20-15SE-EB
JL04V-8A20-
15SE-EB
JL04-2022CK(09)
φ
6.5 (
φ
0.26) to
φ
9.5 (
φ
0.37)
JL04-2022CK(12)
φ
9.5 (
φ
0.37) to
φ
13.0 (
φ
0.51)
JL04-2022CK(14)
φ
12.9 (
φ
0.51) to
φ
15.9 (
φ
0.63)
1.8
2.9
4.4
JL04V-2E24-10PE-B
JL04V-6A24-10SE-EB
or
JA06A-24-10S-J1-EB
JL04V-8A24-
10SE-EB
or
JA08A-24-10S-J1-EB
JL04-2428CK(11)
φ
9.0 (
φ
0.35) to
φ
12.0 (
φ
0.47)
JL04-2428CK(14)
φ
12.0 (
φ
0.47) to
φ
15.0 (
φ
0.59)
JL04-2428CK(17)
φ
15.0 (
φ
0.59) to
φ
18.0 (
φ
0.71)
JL04-2428CK(20)
φ
18.0 (
φ
0.71) to
φ
20.0 (
φ
0.79)
Summary of Contents for SGDH