11.3 List of Parameters
11-29
11
Pn001
Function Selection Application Switches 1
−
−
0000
After
restart
Parameter
No.
Name
Setting Range
Units
Factory
Setting
Setting
Validation
Reference
Section
0
1
2
0
1
2
Stops the motor by applying dynamic brake (DB).
Stops the motor by applying dynamic brake (DB) and then releases DB.
Makes the motor coast to a stop state without using the dynamic brake (DB).
Same setting as Pn001.0 (Stops the motor
by applying DB
or
by coasting
).
Sets the torque of Pn406 to the maximum value,
decelerate the motor to a stop
, and then sets it
to
servolock state
.
Sets the torque of Pn406 to the maximum value,
decelerates the motor to a stop
, and then sets it
to
coasting state
.
Servo OFF or Alarm Stop Mode
(Refer to "8.3.5 Selecting the Stopping Method After Servo OFF.")
Overtravel (OT) Stop Mode
(Refer to "8.3.3 Setting the Overtravel Limit Function.")
0
1
Not applicable to DC power input: Input AC power supply through L1, L2 (, and L3) terminals.
AC/DC Power Input Selection
(Refer to "6.1.3 Typical Main Circuit Wirning Examples.")
0
1
ALO1, ALO2, and ALO3 output only
alarm codes.
Warning Code Output Selection
(Refer to "10.1.2 Warning Display.")
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Applicable to DC power input: Input DC power supply between + 1 and
ALO1, ALO2, and ALO3 output both
alarm codes
and
warning codes
. While warning
codes are output, ALM signal output remains ON (normal state).
Summary of Contents for SGDH
Page 435: ...8 3 8...