5.2 Servomotor Main Circuit Wire Size and Connectors
5-35
5
5.2.13 SGMUH Servomotors (6000 min
-1
) Connectors Conforming to IP67 and Euro-
pean Safety Standards
(1) 400 V Servomotors Without Holding Brakes
Select a cable clamp in accordance with the applied cable diameter.
The straight plug type JA06A-22-22S-J1-EB and L-shaped plug type JA08A-22-22S-J1-EB conform to IP67 Protective
Construction Standard only.
INFO
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Applicable Cable
Range in mm (inch)
(For reference)
Straight
L-shaped
1.0
1.5
CE05-2A18-10PD-B
CE05-6A18-10SD-
B-BSS
CE05-8A18-10SD-B-
BAS
CE3057-10A-1
φ
10.5 (
φ
0.41) to
φ
14.1 (
φ
0.56)
CE3057-10A-2
φ
8.5 (
φ
0.33) to
φ
11.0 (
φ
0.43)
CE3057-10A-3
φ
6.5 (
φ
0.26) to
φ
8.7 (
φ
0.34)
3.0
4.0
JL04HV-2E22-22PE-B
JL04V-6A22-22SE-EB
or
JA06A-22-22S-J1-EB
JL04V-8A22-22SE-EB
or
JA08A-22-22S-J1-EB
JL04-2022CK(09)
φ
6.5 (
φ
0.26) to
φ
9.5 (
φ
0.37)
JL04-2022CK(12)
φ
9.5 (
φ
0.37) to
φ
13.0 (
φ
0.51)
JL04-2022CK(14)
φ
12.9 (
φ
0.51) to
φ
15.9 (
φ
0.63)
Summary of Contents for SGDH