CHAPTER 9
• CLICK 110
87
Figure 9.6 – Click 110 DIP Switches
The Click 110 features three DIP switches labeled S1, S2 and S3 on the label and in the pic-
ture above. (The fourth switch, labeled S4, is currently not used.) Each DIP switch is used to
configure one or two different settings, for a total of six different configurable parameters:
˽
Bus 1 baud rate
˽
Bus 2 baud rate
˽
Channel enable
˽
Channel input map
˽
Outstation mode
˽
Fault latch
Each parameter (except fault latch and outstation mode) has a way to pick between Hard-
ware/Software modes. If Software mode is selected, the parameter must be configured using
the front panel menu or Click Supervisor. If Hardware mode is selected, the parameter can
be configured using the switches. In this case, the setting can be viewed but not changed via
Click Supervisor and the front panel menu.
Baud Rate
The baud rates for the two RS-485 buses, bus 1 and bus 2 (see the faceplate of the device for
which RJ-11 jacks are for each bus), may be independently configured using the switches
on the first DIP switch, labeled S1.