132
CHAPTER 11
•
CLICK 120/121
3
Wire from the A2– terminal on the coil side of each relay to the correct output termi-
nals on the contact closure device or traffic controller.
4
Wire from the 14 terminal on the contact side of each relay to its corresponding light in
the traffic signal (for example, make sure the relay that is wired to the contact closure
output for the red light is then wired into the red light itself).
5
Wire the appropriate voltage and current for the traffic signal to the 11 terminal on
each relay.