CHAPTER 26
• CLICK 330/331
221
Status
Meaning
On
Supply voltage is in an acceptable range
Off
Supply voltage is too low
Table 25.1 – Power Monitor LEDs
˽
Each Ethernet port has two LEDs that show the data transmission speed of that port,
as shown in Table 25.2. These LEDs are labeled 100/ACT and 1000/ACT. If the LED
is on, there is an electrical link. If the LED blinks, there is currently network traffic at
that speed.
LED
10 Mbps
100 Mbps
1000 Mbps
100/ACT
On or blinking
On or blinking
Off
1000/ACT
On or blinking
Off
On or blinking
Table 25.2 – Ethernet Port Monitor LEDs
˽
The fiber ports on the Click 331 each have an LED labeled 1000 LNK/ACT. If this LED
is on, there is a valid connection through that port. If the LED blinks, there is currently
network traffic at 1000 Mbps.
Installation
Unlike many other Click devices, the Click 330/331 do not mount over the T-bus, meaning
that power and communications will have to be wired in.
Wiring Power and Communication
The first four screw terminals, marked US1, GND, US2 and GND, are for wiring in power.
The other two, which are labeled R1 and R2, are for security and functionality alarm pur-
poses (see Figure 25.3).
Figure 25.3 – Wiring the Click 330/331
Summary of Contents for Click 100
Page 1: ...Click 100 400 Series USER GUIDE...
Page 11: ......
Page 17: ......
Page 27: ......
Page 41: ......
Page 43: ......
Page 79: ......
Page 129: ......
Page 145: ......
Page 161: ......
Page 175: ......
Page 183: ......
Page 187: ......
Page 207: ......
Page 219: ......
Page 225: ......
Page 245: ......
Page 259: ......
Page 260: ...www wavetronix com...