148
CHAPTER 13
•
CLICK 200
Follow the steps below to include surge protection using Click 200 devices (see Figure 13.3):
1
Install a Click 200 device in a pole-mount box on the same pole as the sensor being
protected.
2
Install another Click 200 in the main traffic cabinet.
3
Connect the cable from the sensor to the PROTECTED side of the Click 200 in the
pole-mount cabinet. The SmartSensor cable should be kept as short as possible.
4
Connect a cable from the UNPROTECTED side of the Click 200 on the pole to the
UNPROTECTED side of the Click 200 in the main traffic cabinet (see the section on
wiring for how to do this).
Smart
Sensor
120
VAC
Main Traffic Cabinet
Pole
Mount
Traffic
Cabinet
Both ends of the homerun
cable connect to the
UNPROTECTED side of
the surge modules.
Figure 13.3 – Standard SmartSensor Installation Using Homerun Cable
Wiring the Cable
Figure 13.4 below shows how to wire the two sides of the Click 200. The UNPROTECTED
side of the Click 200 is not surge protected and is designed to be connected to the source(s)
from which power surges may come.
Note
It is important to note that there are two different cables that could be used with
the Click 200. All new SmartSensor HD and V sensors are sold with the 8-conductor
cable, so that’s what this lesson will discuss. Older installations, however, may still
have the 9-conductor cable, often just called the SmartSensor cable. Differences in
the wiring of the 9-conductor cable are noted below.
Summary of Contents for Click 100
Page 1: ...Click 100 400 Series USER GUIDE...
Page 11: ......
Page 17: ......
Page 27: ......
Page 41: ......
Page 43: ......
Page 79: ......
Page 129: ......
Page 145: ......
Page 161: ......
Page 175: ......
Page 183: ......
Page 187: ......
Page 207: ......
Page 219: ......
Page 225: ......
Page 245: ......
Page 259: ......
Page 260: ...www wavetronix com...