6-16
TM-500 User’s Guide
Nozzle Positioning Tips
D292144.9.fm
Nozzle Positioning Tips
If components are not dropped properly, there are four variables that can be adjusted to correct
the problem.
Note:
Each part is different and may require a different combination of adjustments to
obtain proper place performance.
1.
Adjust Blow-off Pressure.
The
Blow-off Pressure
Gauge
is
located on the left side of the
Pick Head Bridge
. If components are
not dropping properly, pull the gauge out and rotate to adjust
pressure levels. When the desired pressure level is reached, push
the gauge back in.
Note:
Every part is different and may require a different combina-
tion of adjustments to obtain proper place performance.
2.
Adjust Place Position X
. Open the
Head Set-up Tab
.
Jog the head left or right until the nozzle is centered correctly over
the place location. When the nozzle is positioned correctly, press the
Teach Place Positions
button.