D292144.9.fm
Sensor Adjustments
Chapter 6: Troubleshooting
6-23
Adjusting the Empty Pocket Detector
Empty Pocket Detection
is one of five sensors that come
with the standard TM-500. The EPD alerts the operator if
a carrier tape pocket is empty before the tape advances
through the sealer, allowing the operator to manually fill
the pocket.
Note:
EPD should be enabled if the
Taper Output
Module
is being used without 2D Inspection.
1.
Position the EPD sensor over an empty pocket. The
position of the sensor can be adjusted by moving the
support arm into the desired position over the track.
2.
Count the number of pockets between the EPD and
the nozzle when it is in place position. Include the
pocket which is under the EPD.
3.
Open the HMI
Taper Tab
. Enter the value determined
in Step 2 in the
Pockets to Detect
field in the
EPD
Sensor
section of the screen.
4.
Locate the
EPD Amplifier
. It is the center amplifier in
the group of three amplifiers on the
Cover Tape Arm
.
5.
Press the
SET
buttons on
the EPD amplifier.
6.
Place a component into the pocket the sensor has been positioned over and press the
SET
button again. The sensor amplifier will then be programmed to differentiate an empty pocket
from a pocket with a component placed in it.
7.
If sensor sensitivity needs to be fine tuned, adjust the amplifier setting up or down. For
more information on the sensor/amplifier, refer to
Appendix A: Sensors
Note
: The sensor must be reset for each new type of part to be taped.
Summary of Contents for TM-500
Page 2: ...European Representative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands...
Page 17: ...Contact Information D292144 2 fm xiv...
Page 21: ...Table of Contents D292144 3a fm...
Page 47: ...2 14 TM 500 User s Guide Dual Tray Feeder Input Output Module D292144 5 fm...
Page 83: ...3 36 TM 500 User s Guide The Setup Screens D292144 6 fm...
Page 187: ...7 14 TM 500 User s Guide Ethernet Networks D292144 10 fm...