D292144.10.fm
Maintenance
Chapter 7: Maintenance
7- 11
Check Actuator Belt Tension
The Actuator Belt tension should be measured after its first 30-40 hours of run time, then annu-
ally after that. To measure belt tension, follow the instructions below.
1.
Loosen the (4) M6 x 20mm BHCS on the front, right end of the Bridge.
2.
Loosen the M5 x 16mm Shoulder Screw on the right side of the Bridge.
3.
Lubricate the shoulder of the screw and the screw threads with Super Lube multi-purpose
grease.
4.
Use an inch/pound torque wrench to torque the tensioning bolt to 10 inch/pounds.
Note:
For additional information, see 292586 Idler Assembly Drawing in the Exploded
Views section of this User’s Guide. Contact V-TEK Service for tensioning procedure if belt
tension is outside tolerance.