3-26
TM-500 User’s Guide
The Setup Screens
D292144.6.fm
The
Carrier Low
button turns the
Carrier Tape Low Sensor
on and off. The
Carrier Tape Low
Sensor
detects when the carrier tape reel is running low. When the
Carrier Tape Low Sensor
is
activated, an error message appears at the bottom of the HMI screen. The recommended setting
for the
Carrier Motion Sensor
is
ON
.
The
Carrier Motion
button turns the
Carrier Motion Sensor
on and off. The
Carrier Motion Sen-
sor
detects when the carrier tape has stopped moving due to a tape jam or breakage. If the
Car-
rier Motion Sensor
is triggered, the job that is being run is paused and an error message appears
at the bottom of the HMI screen. The recommended setting for the
Carrier Motion Sensor
is
ON
.
The
Empty Pocket Detect
button turns the
EPD Sensor
on and off. The
EPD Sensor
detects
when a carrier tape pocket is empty. If the
EPD Sensor
is activated during a job, the job that is
being run is paused and an error message appears at the bottom of the HMI screen.
Note:
The recommended setting for the
Carrier Motion Sensor
is
ON
if the
2D Vision
Module
is not installed. If
2D Vision
is installed, EPD is unnecessary as the camera auto-
matically detects empty carrier tape pockets, therefore it is not visible on the
Taper Tab
.
When EPD is enabled, the
Pockets Until Detection
field is also active. Count the number of
pockets from the EPD Sensor to the nozzle, including the pocket under the EPD Sensor. Enter
this number in the
Pockets To Detect
field
Summary of Contents for TM-500
Page 2: ...European Representative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands...
Page 17: ...Contact Information D292144 2 fm xiv...
Page 21: ...Table of Contents D292144 3a fm...
Page 47: ...2 14 TM 500 User s Guide Dual Tray Feeder Input Output Module D292144 5 fm...
Page 83: ...3 36 TM 500 User s Guide The Setup Screens D292144 6 fm...
Page 187: ...7 14 TM 500 User s Guide Ethernet Networks D292144 10 fm...