EMIF
7.3.2 Integration
7.3.2.1
EMIF Connectivity Attributes
The general connectivity attributes for the EMIF are shown in
Table 7-94. EMIF Connectivity Attributes
Attributes
Type
Power Domain
Peripheral Domain
Clock Domain
PD_PER_L3_GCLK (OCP)
PD_PER_EMIF_GCLK (Func)
Reset Signals
POR_N
Idle/Wakeup Signals
Smart Idle
Interrupt Requests
1 interrupt to MPU Subsystem (DDRERR0)
DMA Requests
None
Physical Address
L3 Fast Slave Port
7.3.2.2
EMIF Clock Management
The EMIF4 OCP interface (ocp_clk) is clocked by the L3 Fast clock sourced from the Core PLL. The DDR
Command and Data macros are clocked by the DDR PLL. The PRCM divides this clock by two to create
the EMIF functional clock (m_clk).
The OCP and functional clocks may be asynchronous because synchronization is managed in the EMIF4
internal FIFO (EMIF4 is set in asynchronous mode).
Table 7-95. EMIF Clock Signals
Clock Signal
Maximum Frequency
Reference Source
Comments
ocp_clk
200 MHz
CORE_CLKOUTM4
pd_per_l3_gclk
(Interface clock)
From PRCM
m_clk
152 MHz
DDR PLL CLKOUT / 2
pd_per_emif_gclk
(EMIF functional clock)
From PRCM
400 MHz
DDR PLL CLKOUT
clkout_po
cmd0_dfi_clk
From DDR PLL
cmd1_dfi_clk
cmd2_dfi_clk
data0_dfi_clk
data1_dfi_clk
(Macro clocks)
7.3.2.3
EMIF Pin List
The EMIF/DDR external interface signals are shown in
Table 7-96. EMIF Pin List
Pin
Type
Description
DDR_CK
O
Differential clock pair
DDR_NCK
DDR_CKE
O
Clock enable
DDR_CSn0
O
Chip select
DDR_RASn
O
Row address strobe
DDR_CASn
O
Column address strobe
DDR_WEn
O
Write enable
DDR_BA[2:0]
O
Bank address
402 Memory Subsystem
SPRUH73H – October 2011 – Revised April 2013