Ethernet Subsystem Registers
Table 14-152. P1_CONTROL Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
10
P1_TS_130
R/W
0h
Port 1 Time Sync Destination IP Address 130 enable
0 - disabled
1 - Annex D (UDP/IPv4) time sync packet destination IP address
number 130 (decimal) is enabled.
9
P1_TS_129
R/W
0h
Port 1 Time Sync Destination IP Address 129 enable
0 - disabled
1 - Annex D (UDP/IPv4) time sync packet destination IP address
number 129 (decimal) is enabled.
8
P1_TS_TTL_NONZERO
R/W
0h
Port 1 Time Sync Time To Live Non-zero enable.
0 = TTL must be zero.
1 = TTL may be any value.
4
P1_TS_ANNEX_D_EN
R/W
0h
Port 1 Time Sync Annex D enable
0 - Annex D disabled
1 - Annex D enabled
3
P1_TS_LTYPE2_EN
R
0h
Port 1 Time Sync LTYPE 2 enable
0 - disabled
1 - enabled
2
P1_TS_LTYPE1_EN
R/W
0h
Port 1 Time Sync LTYPE 1 enable
0 - disabled
1 - enabled
1
P1_TS_TX_EN
R/W
0h
Port 1 Time Sync Transmit Enable
0 - disabled
1 - enabled
0
P1_TS_RX_EN
R/W
0h
Port 1 Time Sync Receive Enable
0 - Port 1 Receive Time Sync disabled
1 - Port 1 Receive Time Sync enabled
1374
Ethernet Subsystem
SPRUH73H – October 2011 – Revised April 2013