TP16-256
- Installer Manual
Control by Console
6-7
On the display are viewed in sequence all the zones included in the programs
selected.
Exclude the zone selected pressing:
+
#
(YES)
to exclude the zone selected
Select another zone to be excluded with the keys arrow up and arrow down or
exclude sequential zones pressing repeatedly # (hash).
Once you have excluded all the zones you wanted to exclude, it is possible to confirm
the exclusion and procede with arming without awaiting expiry of the zone exclusion
time by pressing:
+
EXIT
to confirm the exclusion and abort the zone exclusion time
If all the zones are excluded, the process is stopped automatically.
IMMEDIATE CONFIRMATION OF ARMING
The zone exclusion time stops approximately after 10 seconds from the exclusion of
the last zone.
It is possible to abort the wait and obtain immediate arming by pressing:
+
#
The zones remain excluded until disarming of the program. They are activated
automatically again the next time the program is armed.
6.1.1.3 TOTAL ARMING
After entering the master code and during the 10 seconds destinated for the selection
of the programs, it is possible to obtain total arming, i.e. arming of all the programs by
pressing:
+
#
(YES)
to arm all the programs
The control panel initiates the zone exclusion time.
The corresponding yellow program LED start blinking.
6.1.2 ARMING WITH STANDARD USER CODE
Whereas the master code is always enabled for all the programs, the user codes
control merely those programs they have been enabled for by the installer or the
holder of the master code.
Enter the user code appropriately programmed, e.g. standard user code number 1:
+
11111
For the 10 seconds to come, it is possible to select the programs to be armed/
disarmed (pressing the program number once the program is selected, pressing it
again the program is deselected).
On every keystroke the counter is reset.
Select the programs to be armed, e.g.:
+
1 2 3
Procede as for arming with master code (§ 6.1.1).
6.1.2.1 TOTAL ARMING
See § 6.1.1.3
EXCLUDE ? with #
Zone xxx
WARNING
The zones definded as NOT EXCLUDIBLE are not listed. If a zone is already excluded it does not
appear in the list either.
WARNING
The programs that are already armed are not influenced.
To abort arming of the programs selected press the
EXIT
key. The process is aborted and the
control panel returns to stand-by.
- ACCESS -
Master
- ACCESS -
User 001
WARNING
Since it is possible to program up to 32 programs and the numbers superior to 9 must be composed
entering the tens first and then the units, in order to avoid erroneous arming when you wish to arm
the programs 1, 2 and 3 it is recommended to put a 0 in front of the number (e.g. 01) or let elapse at
least one second between the keys, whereas for selection of the programs 11, 12 etc. press the keys
quickly one after the other (within one second).
The programs that are already armed and those the standard user code in question is not enabled
for are not influenced.
To abort arming of the programs selected press the
EXIT
key. The process is aborted and the
control panel returns to stand-by.
Summary of Contents for TP16-256
Page 4: ...IV Installer Manual TP16 256...
Page 12: ...Index Installer Manual TP16 256 8...
Page 16: ...General Features Installer Manual TP16 256 1 4...
Page 18: ...Hardware Installer Manual TP16 256 2 2...
Page 30: ...Hardware Installer Manual TP16 256 2 14...
Page 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Page 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Page 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Page 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Page 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Page 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Page 86: ...Set up Installer Manual TP16 256 3 6...
Page 91: ...TP16 256 Installer Manual Set up 3 11...
Page 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Page 196: ...Control by Console Installer Manual TP16 256 6 16...
Page 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Page 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Page 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Page 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Page 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Page 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...