Programming by Console
Installer Manual -
TP16-256
5-34
MENU
11
11
11
11
11
5.18
PROGRAMMING OF THE CODES
+
yw
to select the menu (11)
+
#
YES
to confirm the selection
Submenus
z
Length
Defines the number of digits of all the codes of the system (from 4 to 6 digits)
z
Inst. code (installer code)
Defines the installer code
z
Master code
Defines the master code and its attributes
z
User codes
Defines the user codes (1 to 200) and permits their parameterization
Commands available
+
yw
to select the parameter
+
#
YES
to confirm the selection
5.18.1
PROGRAMMING OF THE CODE LENGTH
The code length can be set to 4, 5 or 6 digits. It determines the number of digits of all
the codes of the system.
Commands available
+
4
...
6
to enter the value
+
EXIT
to accept programming and quit the submenu
5.18.2
PROGRAMMING OF THE INSTALLER CODE
Commands available
+
yw
to delete an existing code
+
0
...
9
to enter the value
+
EXIT
to accept programming and quit the submenu
5.18.3
PROGRAMMING OF THE MASTER CODE
The master code is usually reserved to the owner of the system. It is always enabled
for all the programs of the system.
Submenus
z
By-pass
Enables the code for activation/deactivation of by-pass instead of arming/
disarming
z
Byp gen. al. (by-pass general alarms)
Enables the code so as to by-pass general alarms in order to arm the system in
the presence of one of the following alarm conditions: tamper, low battery, power
failure, supervision, trouble module
z
Hold-up
Enables the code for the hold-up function. Under duress, the user will then be
able to release a silent alarm by apparently disarming the system entering the
proper code and decrementing the last figure by one unity. Example: if the master
code is 12345, the hold-up code will be 12344, if the code ends in 0 (e.g. 12340),
the hold-up code ends in 9 (12349).
z
Autom. abort (automatic communicator block on disarming)
Enables the code for blocking of the active phone call cycles and those queued
up automatically on disarming (entering of the code).
z
Manual abort (manual communicator block)
Enables the manual communicator block after disarming (entering the code).
Entering the code again followed by the EXIT key all the active phone call cycles
and those queued up are interrupted.
z
Remote disab. (disabling of remote arming/disarming by phone)
Disables
the code for arming/disarming of the programs (programmed
appropriately) by phone.
z
Direct disab. (disabling of direct arming/disarming)
Disables
the code for direct arming, i.e. simultaneous arming of all the programs
associated by entering the code followed by the #(hash) key, but is obliged to
select them manually.
z
Privileged
Defines the code as privileged. In addition to the standard functions, the user will
Menu
11
Codes
Codes
1
Length
Codes
2
Inst. code
Codes
3
Master code
Master code
1
Code
Master code
2
Attributes
Summary of Contents for TP16-256
Page 4: ...IV Installer Manual TP16 256...
Page 12: ...Index Installer Manual TP16 256 8...
Page 16: ...General Features Installer Manual TP16 256 1 4...
Page 18: ...Hardware Installer Manual TP16 256 2 2...
Page 30: ...Hardware Installer Manual TP16 256 2 14...
Page 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Page 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Page 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Page 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Page 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Page 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Page 86: ...Set up Installer Manual TP16 256 3 6...
Page 91: ...TP16 256 Installer Manual Set up 3 11...
Page 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Page 196: ...Control by Console Installer Manual TP16 256 6 16...
Page 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Page 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Page 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Page 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Page 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Page 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...