TP16-256
- Installer Manual
Programming by PC
4-17
AFTER BLINKING
Defines the time blinking is to continue (in minutes) once the alarm has been stopped.
VOLUME SIGNALING/PREALARM
Defines the sound level signaling (low, medium low, medium high, high).
SIREN MODE
Two modes available:
z
Indoor siren
Modes, time and tipical sounds of indoor siren
z
Outdoor siren
Modes, time and tipical sounds of outdoor siren
ALARM
The siren is actived in case of at least one of the programs it is associated to (observing the relative time
settings) and in case of general alarm (tamper, trouble,...).
Sound type available:
z
Bidirectional sweep tone (default setting)
z
Monodirectional sweep tone
z
Bitone
TECHNICAL ALARM
The siren is actived if the technical zone is not included in any program at all or if it is included in one of the
programs the siren is associated to.
Sound type available:
z
Bidirectional sweep tone (default setting)
z
Monodirectional sweep tone
z
Bitone
PREALARM
The siren is actived in case of prealarm of at least one of the programs it is associated to.
The sound type is fixed.
SIGNALING
The siren is actived in case of arming/disarming of the programms it is associated to.
The sound type is fixed.
CHIME
The siren is actived if chime zone opened is not included in any program at all or if it is included in one of the
programs the siren is associated to.
The sound type is fixed.
ENABLING OF ANTIFOAM
Permits enabling/disabling of the optical antifoam protection.
ENABLING OF ANTIDRILLING
Permits enabling/disabling of the antidrilling protection.
ACTIVATION MODE
Determines the activation mode of the siren for the events detected from the control panel:
z
Not active
The siren is not active at all
z
Sounding
Only sounding is actived
z
Flashing light
Only flashing light is actived
z
So Flashing light
Sounding and falshing light are actived
To enable an option, click on the box beside it.
Once all the options required have been enabled, press:
z
OK
to confirm and quit
z
Abandon
to quit without saving
Summary of Contents for TP16-256
Page 4: ...IV Installer Manual TP16 256...
Page 12: ...Index Installer Manual TP16 256 8...
Page 16: ...General Features Installer Manual TP16 256 1 4...
Page 18: ...Hardware Installer Manual TP16 256 2 2...
Page 30: ...Hardware Installer Manual TP16 256 2 14...
Page 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Page 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Page 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Page 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Page 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Page 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Page 86: ...Set up Installer Manual TP16 256 3 6...
Page 91: ...TP16 256 Installer Manual Set up 3 11...
Page 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Page 196: ...Control by Console Installer Manual TP16 256 6 16...
Page 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Page 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Page 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Page 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Page 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Page 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...