Control by Keypoint
Installer Manual -
TP16-256
7-10
7.4.1.1 ARMING WITH CODE
Enter a valid code (master or standard user code enabled for the programs to be
armed), e.g. master code (default code 12345):
+
12345
The green LED 5 is lit.
For the 8 seconds to come it is possible to select the programs to be armed/disarmed
(pressing the program number the first time the program is selected, pressing it the
second time it is deselected). On every keystroke the counter is reset.
Select the programs to be armed, e.g.:
+
1 3
The red LED corresponding to the programs selected start blinking.
+
#
to confirm the selection and stop the counter without waiting for 8 seconds.
ZONE EXCLUSION TIME
For 8 seconds after selecting the programs, it is possible to exclude manually some of
the zones from the detection of alarms with a procedure explained lateron.
If you do not wish to exclude any zone, it is possible to confirm the selection without
waiting for expiry of the zone exclusion time by pressing # (hash) again:
+
#
to confirm the selection and abort the zone exclusion time
EXIT TIME
The zones defined as delayed upon arming observe the exit time programmed by the
installer.
If the programs selected contain delayed zones, on expiry of the zone exclusion time
follows the exit time and the programs in question are only armed on expiry of the exit
time.
Once the exit time has expired, the program LED become lit and remain lit until
disarming of these programs.
If the programs selected do not contain delayed zones, on expiry (or abort) of the
zone exclusion time, the programs in question are armed and the corresponding red
LED become lit immediately.
7.4.1.2 EXCLUSION OF OPEN ZONES
After selecting the programs to be armed, during the 8-seconds zone exclusion time, if
there are open zones (direct or delayed type 2), the yellow LED 7 OCG is blinking.
A zone can result open for instance in case of fault of the detector connected.
To arm the programs selected excluding the open zones press:
+
*
7.4.1.3 QUICK ARMING
- Not permitted -
7.4.1.4 ARMING DURING THE ACCESS PERIODS
It is possible to define up to 8 access periods of the codes. As a consequence, the
codes are enabled for arming and disarming during the access periods associated by
the installer or the holder of the master code only.
WARNING
The electronic keypad permits the control of only 4 of the 32 programs. The status of the other
programs is not viewed by the LED on the electronic keypad.
The 4 program LED are associated by default to the first 4 programs of the control panel. The
installer can associate the LED to any of the 32 programs.
WARNING
Whereas the master code is always enabled for all the programs, the user codes control merely
those programs they have been enabled for by the installer or the holder of the master code.
WARNING
If the open zones are not excluded, on expiry of the zone exclusion time (and perhaps the exit time)
the programs are armed and the open zones are activated. As a consequence, the alarm is
released.
Summary of Contents for TP16-256
Page 4: ...IV Installer Manual TP16 256...
Page 12: ...Index Installer Manual TP16 256 8...
Page 16: ...General Features Installer Manual TP16 256 1 4...
Page 18: ...Hardware Installer Manual TP16 256 2 2...
Page 30: ...Hardware Installer Manual TP16 256 2 14...
Page 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Page 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Page 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Page 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Page 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Page 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Page 86: ...Set up Installer Manual TP16 256 3 6...
Page 91: ...TP16 256 Installer Manual Set up 3 11...
Page 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Page 196: ...Control by Console Installer Manual TP16 256 6 16...
Page 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Page 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Page 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Page 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Page 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Page 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...