Programming by Console
Installer Manual -
TP16-256
5-24
MENU
13
13
13
13
13
5.14
CONFIGURATION OF THE WIRELESS KEYS
+
yw
to select the menu (13)
+
#
YES
to confirm the selection
The control panel provides up to 60 wireless keys with three function keys each. The
wireless keys can be programmed individually so as to execute different functions.
SELECTION OF THE WIRELESS KEY
+
yw
to select the wireless key (from 1 to 60)
+
#
YES
to confirm the selection
Submenus
z
Periods
Defines the access period (from 1 to 8) during which the wireless key is enabled
z
Ass. buttons
Permits the association of the following functions to the 3 function keys:
Disarming (of all the programs that have previously been armed by the
wireless key)
Arm. program (a determined program from 1 to 16)
Dis. program (a determined program from 1 to 16)
ON/OFF rem ctrl (a determined remote control from 1 to 16)
ON rem ctrl (a determined remote control from 1 to 16)
OFF rem ctrl (a determined remote control from 1 to 16)
z
Attributes
By-pass
Defines whether the wireless keys is to be used for arming and disarming or
activation and deactivation of by-pass. If the attribute is selected, the function
of the arming and disarming keys change as follows:
-
Arm. program becomes activation of by-pass of the program
-
Dis. program becomes deactivation of by-pass of the program
-
Disarming becomes general deactivation of by-pass
Conf. dis (confirmation of disarming)
If the attribute is selected, disarming by wireless key releases a hold-up alarm
unless it is confirmed by entering a valid code within the delay programmed
(see programming of time parameters). If the code is entered either not at all
or late, a silent hold-up alarm is released and the outputs programmed are
activated.
Autom. abort (automatic communicator block on disarming)
If the attribute is selected, upon disarming by wireless key all the active
telephone channels as well as those waiting to be activated are blocked.
Byp gen. al. (by-pass general alarms)
Permits the by-pass of the general alarms, i.e. arming in the presence of the
following alarms:
-
Tamper
-
Low battery
-
Power failure
-
Supervision
-
Trouble
Duress
Enables the release of a panic alarm by pressing the keys 2 and 3 of the
wireless key simultaneously.
Excl. disab.
Disables
both the voluntary exclusion of zones and the automatic exclusion of
open zones. If the control panel is armed in the presence of open zones, these
will release an alarm at the end of the arming phase.
z
Learning (see § 5.14.1)
Viewing of the current settings
[ ] Attribute has not been associated to the wireless key selected
[ # ] Attribute has been associated to the wireless key selected
Commands available
+
#
YES
to associate the function to the wireless key
+
*
NO
to cancel an existing association
+
EXIT
to confirm and quit
Menu
13
WL keys
WL keys
1
Periods
WL keys
2
Ass. buttons
WL keys
3
Attributes
WL keys
4
Learning
Summary of Contents for TP16-256
Page 4: ...IV Installer Manual TP16 256...
Page 12: ...Index Installer Manual TP16 256 8...
Page 16: ...General Features Installer Manual TP16 256 1 4...
Page 18: ...Hardware Installer Manual TP16 256 2 2...
Page 30: ...Hardware Installer Manual TP16 256 2 14...
Page 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Page 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Page 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Page 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Page 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Page 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Page 86: ...Set up Installer Manual TP16 256 3 6...
Page 91: ...TP16 256 Installer Manual Set up 3 11...
Page 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Page 196: ...Control by Console Installer Manual TP16 256 6 16...
Page 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Page 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Page 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Page 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Page 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Page 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...