Technical alarm
The siren is actived if the technical zone in alarm is not included in any program
at all or if it is included in one of the programs the siren is associated to.
Sound type available:
Sound 1 -
Bidirectional sweep tone (default setting)
Sound 2 -
Monodirectional sweep tone
Sound 3 -
Bitone
z
Prealarm
The siren is actived in case of prealarm of at least one of the programs it is
associated to. The sound type is fixed.
z
Signaling
The siren is actived in case of arming/disarming of the programs it is associated
to. The sound type is fixed.
z
Chime
The siren is actived if the chime zone opened is not included in any program at all
or if it is included in one of the programs the siren is associated to. The sound
type is fixed.
z
Attributes
Enabling antifoam
Enabling antidrilling
z
Activation mode
Determines the activation mode of the siren for the selected events:
Not active
The siren is not activated at all
Sounding
Only sounding is activated
Flashing light
Only flashing light is activated
So Flashing light
Sounding and falshing light are activated
Viewing of the current settings
[ ] Function disabled
[ # ] Function enabled
Commands available
+
yw
to select the function
+
#
YES
to select and activate the function
+
*
NO
to deactivate the function
+
EXIT
to confirm and quit the submenu
5.10
PROGRAMMING OF THE TIMERS
+
yw
to select the menu (9)
+
#
YES
to confirm the selection
Submenu
z
Test call
Configuration of the remote functioning check of the control
panel
z
Timers
Configuration of the 32 timers
z
Acc. periods
Programming of 8 access periods for the codes, keys and
wireless keys
Commands available
+
yw
to select the function
+
#
YES
to confirm the selection
5.10.1
TEST CALL
The test call is a remote functioning check of the control panel that is executed with
scheduled intervals. It consists in one or more telephone calls made by the telephone
channels programmed accordingly (see programming of the report codes) towards the
telephone number/s programmed.
Submenu
z
Period
Values from 0 to 255
z
Attr. period
Time unit (not active, minutes, hours, days) that will be
associated to the value entered before
z
Armed
Permits binding of the execution of the test call to system
status (i.e. always or only if the control panel is armed)
z
Begin. time
Defines the starting hour of the test call cycle
Commands available
+
yw
to select the parameter
+
#
YES
to confirm the selection
Menu
9
Timers
Timers
1
Test call
Timers
2
Timers
Timers
3
Acc. periods
Test call
1
Period
Test call
2
Attr. Period
Test call
3
Armed
[ ]
Test call
4
Begin. time [ : ]
Summary of Contents for TP16-256
Page 4: ...IV Installer Manual TP16 256...
Page 12: ...Index Installer Manual TP16 256 8...
Page 16: ...General Features Installer Manual TP16 256 1 4...
Page 18: ...Hardware Installer Manual TP16 256 2 2...
Page 30: ...Hardware Installer Manual TP16 256 2 14...
Page 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Page 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Page 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Page 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Page 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Page 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Page 86: ...Set up Installer Manual TP16 256 3 6...
Page 91: ...TP16 256 Installer Manual Set up 3 11...
Page 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Page 196: ...Control by Console Installer Manual TP16 256 6 16...
Page 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Page 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Page 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Page 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Page 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Page 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...