Select the function by clicking on the function key, then check the zones to be associated. The zones may be
identified either by the zone number or the description assigned beforehand.
Once you have finished the zone-function association, press:
z
OK
to confirm and close the zone configuration tables
z
Abandon
to undo the zone-function association
4.1.3
ZONE-PROGRAM ASSOCIATION
Open the zone configuration tables and select the zone-program window by clicking on the tab
Zone-Programs
.
On the screen is viewed:
The zone-program window permits the creation of the programs.
The program is a group of zones (1 to 256) that are enabled altogether for the detection of alarms upon arming of the
program. The programs can be armed singularly, i.e. one program at a time (single arming), or simultaneously, i.e.
several programs at the same time (multiple arming).
The zones of a determined program are enabled simultaneously for the detection of alarms, exception made of the
delayed, walk through and common zones. The delayed and the walk through zones will be enabled upon expiry of
the exit time associated. The common zones will be enabled only if all the programs they are included in are armed.
The zones that are not included in the programs armed, are not enabled for the detection of alarms, exception made
of the technical, hold-up and tamper zones that are always enabled even if the system is completely disarmed.
The control panel TP16-256 permits the creation of maximum 32 programs, every program can be composed of
maximum 256 zones.
Summary of Contents for TP16-256
Page 4: ...IV Installer Manual TP16 256...
Page 12: ...Index Installer Manual TP16 256 8...
Page 16: ...General Features Installer Manual TP16 256 1 4...
Page 18: ...Hardware Installer Manual TP16 256 2 2...
Page 30: ...Hardware Installer Manual TP16 256 2 14...
Page 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Page 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Page 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Page 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Page 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Page 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Page 86: ...Set up Installer Manual TP16 256 3 6...
Page 91: ...TP16 256 Installer Manual Set up 3 11...
Page 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Page 196: ...Control by Console Installer Manual TP16 256 6 16...
Page 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Page 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Page 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Page 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Page 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Page 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...