Programming by Console
Installer Manual -
TP16-256
5-30
5.15.5.1
PROGRAMMING OF THE EMERGENCY NUMBER
The telephone communicator with GSM module constantly communicates via RS485
serial bus with the control panel. If communication fails for more than 30 seconds
(serial bus not connected or defect), the emergency call is made transmitting the
emergency message selected (from 1 to 4) to the telephone number programmed.
The emergency number can be composed of max. 15 digits.
Commands available
+
yw
to delete an existing number
+
#*
to insert the DTMF symbols #(hash) and *(star)
+
MEM
to insert a pause
+
0
...
9
to enter the value
+
EXIT
to accept programming and quit the submenu
5.15.5.2
PROGRAMMING OF THE EMERGENCY SMS
Using an external mobile telephone it is possible to program the text of the emergency
SMS and send it to the number of the SIM card of the GSM telephone communicator
TECNOCELL-PRO PL.
RECEPTION OF THE EMERGENCY SMS
Press the hash key
#
YES
to put the control panel into the reception mode. On the
display of the console is viewed
Waiting
.
On reception of the emergency SMS, on display of the console is viewed
Completed
.
The emergency SMS has been stored.
Commands available
+
#
YES
to start the reception
+
EXIT
to accept programming and quit the submenu
5.15.5.3
PROGRAMMING OF THE SMS HEADING
Using an external mobile telephone it is possible to program the text of the SMS
heading and send it to the number of the SIM card of the GSM telephone
communicator TECNOCELL-PRO PL.
RECEPTION OF THE SMS HEADING
Press the hash key #(YES) to put the control panel into the reception mode. On the
display of the console is viewed
Waiting
.
On reception of the SMS heading, on display of the console is viewed
Completed
.
The SMS heading has been stored.
Commands available
+
#
YES
to start the reception
+
EXIT
to accept programming and quit the submenu
5.15.6
GENERAL NOTES ON SMS
SMS FORMAT
The SMS are always composed of a heading (introductory frase) containing general
information and the event description.
A typical heading would be "Control panel TP16-256 Tecnoalarm”.
The event description is identical with that stored in the event log, e.g. “Arming
Program 1 [perimeter]“.
SMS TYPE
There are two types of SMS messages:
z
Traditional SMS (protocol 166)
z
SMS with warning signal (protocol 167)
Prior to transmitting the SMS message, the telephone communicator with GSM
module makes the addressee's mobile phone ring until the latter answers the
phone. If the addressee does not answer the call, the transmission is cancelled.
This is to ensure that the addressee notices the arrival of the SMS message.
Mobile
9
Prog.SMS heading
Prog.SMS heading
Waiting
Prog.SMS heading
Completed
Prog.emer.SMS
Waiting
Prog.emer.SMS
Completed
WARNING
The emergency SMS message can have a maximum length of 80 characters. All further characters
will be cut off.
WARNING
The heading of the SMS messages should not exceed a maximum length of 40 characters. All
further characters will be cut off.
Summary of Contents for TP16-256
Page 4: ...IV Installer Manual TP16 256...
Page 12: ...Index Installer Manual TP16 256 8...
Page 16: ...General Features Installer Manual TP16 256 1 4...
Page 18: ...Hardware Installer Manual TP16 256 2 2...
Page 30: ...Hardware Installer Manual TP16 256 2 14...
Page 46: ...Hardware Input Expansion Modules Installer Manual TP16 256 2A 16...
Page 50: ...Hardware Console Installer Manual TP16 256 2B 4...
Page 59: ...TP16 256 Installer Manual Output Expansion Modules Hardware 2D 5 ADDRESSES 6 TO 13...
Page 68: ...Hardware Programming Interfaces Installer Manual TP16 256 2E 6...
Page 70: ...Hardware Telephone Communicator with GSM Module Installer Manual TP16 256 2F 2...
Page 80: ...Hardware Wireless Expansion Modules Installer Manual TP16 256 2G 10...
Page 86: ...Set up Installer Manual TP16 256 3 6...
Page 91: ...TP16 256 Installer Manual Set up 3 11...
Page 184: ...Control by Console Installer Manual TP16 256 6 4 OPERATIONS WITHOUT CODE...
Page 196: ...Control by Console Installer Manual TP16 256 6 16...
Page 224: ...Technical Specifications Installer Manual TP16 256 8 14...
Page 226: ...Appendix A Transmission Protocols Installer Manual TP16 256 A 2...
Page 230: ...Appendix B Special Procedures Installer Manual TP16 256 B 2...
Page 242: ...Appendix B Special Procedures Installer Manual TP16 256 B 14...
Page 244: ...Appendix C Code Management Installer Manual TP16 256 C 2...
Page 247: ...TP16 256 Installer Manual Code Management Appendix C C 5...