Installation and Reference Manual
System Operation
Installation and Reference Manual v3.2/0410/6
67
The IP address of a PCS 100. This can be viewed by pressing the Down arrow once (or twice if
Favourites are displayed) on the handset, the IP address being used by the handset will be
displayed, eg 192.168.0.245. The IP address is also displayed during power up.
2
The reference number of the port:-
a
Each analogue port on a Phone module or Call Server is given a reference number starting at
5001. Therefore port 1 is referenced as 5001, port 2 as 5002 etc.
b
The port reference number for a PCS 580/570/560/410/400/100 will always be 5001.
3
The User’s Partner Login Code. This can be configured as follows:
Configure a Phone’s Partner Login Code
1
In Manager select Users
2
Select the User who wishes to use the PCS 60 as a partner to their handset
3
Click on the entry within the Initial Phone field eg Phone Module 1.port01
4
You will be taken to the port assigned to this User
5
In the Partner Login Code field enter a 1-8 digit access code, eg 1234
6
Select Update or Apply when ready.
Run the PCS 60 as a partner
1
Run the PCS60 software either from Applications or create an Alias to this file in the required
location and double click on the Alias. (Please note that if you do not wish the PCS 60 to be loaded
initially as an IP soft phone disconnect the PC from the network or turn off Auto Add Phones.)
2
The PCS 60 application will open.
3
From the PCS60 menu select Preferences
4
In the IP Address field enter the IP address
of the Call Server or Phone Module or IP
Phone as described above, eg
192.168.0.249
5
In the Port field enter the port number that the analogue phone is connected to, as described
above, or 5001 for an IP phone.