Rev. 5.00, 09/03, page 75 of 760
2. If using software for way selection for entry replacement, write the desired value to the RC
field in MMUCR.
3. Issue the LDTLB instruction to load the contents of PTEH and PTEL into the TLB.
4. Issue the return from exception handler (RTE) instruction to terminate the handler routine and
return to the instruction stream.
3.5.2
TLB Protection Violation Exception
A TLB protection violation exception results when the virtual address and the address array of the
selected TLB entry are compared and a valid entry is found to match, but the type of access is not
permitted by the access rights specified in the PR field. TLB protection violation exception
processing includes both hardware and software operations.
Hardware Operations: In a TLB protection violation exception, the SH7709S hardware executes
a set of prescribed operations, as follows:
1. The VPN field of the virtual address causing the exception is written to the PTEH register.
2. The virtual address causing the exception is written to the TEA register.
3. Either exception code H'0A0 for a load access, or H'0C0 for a store access, is written to the
EXPEVT register.
4. The PC value indicating the address of the instruction in which the exception occurred is
written into SPC (if the exception occurred in a delay slot, the PC value indicating the address
of the related delayed branch instruction is written into SPC).
5. The contents of SR at the time of the exception are written to SSR.
6. The MD bit in SR is set to 1 to place the SH7709S in the privileged mode.
7. The BL bit in SR is set to 1 to mask any further exception requests.
8. The register bank (RB) bit in SR is set to 1.
9. The way that generated the exception is set in the RC field in MMUCR.
10. Execution branches to the address obtained by adding the value of the VBR contents and
H'00000100 to invoke the TLB protection violation exception handler.
Software (TLB Protection Violation Handler) Operations: Software resolves the TLB
protection violation and issues the RTE (return from exception handler) instruction to terminate
the handler and return to the instruction stream.
Summary of Contents for SH7709S
Page 2: ......
Page 44: ...Rev 5 00 09 03 page xliv of xliv ...
Page 62: ...Rev 5 00 09 03 page 18 of 760 ...
Page 128: ...Rev 5 00 09 03 page 84 of 760 ...
Page 146: ...Rev 5 00 09 03 page 102 of 760 ...
Page 224: ...Rev 5 00 09 03 page 180 of 760 ...
Page 246: ...Rev 5 00 09 03 page 202 of 760 ...
Page 266: ...Rev 5 00 09 03 page 222 of 760 ...
Page 370: ...Rev 5 00 09 03 page 326 of 760 ...
Page 432: ...Rev 5 00 09 03 page 388 of 760 ...
Page 532: ...Rev 5 00 09 03 page 488 of 760 ...
Page 598: ...Rev 5 00 09 03 page 554 of 760 ...
Page 630: ...Rev 5 00 09 03 page 586 of 760 ...
Page 656: ...Rev 5 00 09 03 page 612 of 760 ...
Page 684: ...Rev 5 00 09 03 page 640 of 760 ...
Page 700: ...Rev 5 00 09 03 page 656 of 760 ...
Page 758: ...Rev 5 00 09 03 page 714 of 760 ...
Page 807: ...SH7709S Group Hardware Manual REJ09B0081 0500O ADE 602 250C ...