![Renesas H8SX/1650 Hardware Manual Download Page 510](http://html1.mh-extra.com/html/renesas/h8sx-1650/h8sx-1650_hardware-manual_1440112510.webp)
Section 13 Serial Communication Interface (SCI)
Rev.2.00 Jun. 28, 2007 Page 488 of 666
REJ09B0311-0200
13.4.6
Serial Data Reception (Asynchronous Mode)
Figure 13.8 shows an example of the operation for reception in asynchronous mode. In serial
reception, the SCI operates as described below.
1. The SCI monitors the communication line, and if a start bit is detected, performs internal
synchronization, stores receive data in RSR, and checks the parity bit and stop bit.
2. If an overrun error (when reception of the next data is completed while the RDRF flag in SSR
is still set to 1) occurs, the ORER bit in SSR is set to 1. If the RIE bit in SCR is set to 1 at this
time, an ERI interrupt request is generated. Receive data is not transferred to RDR. The RDRF
flag remains to be set to 1.
3. If a parity error is detected, the PER bit in SSR is set to 1 and receive data is transferred to
RDR. If the RIE bit in SCR is set to 1 at this time, an ERI interrupt request is generated.
4. If a framing error (when the stop bit is 0) is detected, the FER bit in SSR is set to 1 and receive
data is transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an ERI interrupt
request is generated.
5. If reception finishes successfully, the RDRF bit in SSR is set to 1, and receive data is
transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an RXI interrupt request is
generated. Because the RXI interrupt processing routine reads the receive data transferred to
RDR before reception of the next receive data has finished, continuous reception can be
enabled.
RDRF
FER
0
1 frame
D0
D1
D7
0/1
1
0
D0
D1
D7
0/1
0
1
1
Data
Start
bit
Parity
bit
Stop
bit
Start
bit
Data
Parity
bit
Stop
bit
ERI interrupt request
generated by framing
error
Idle state
(mark state)
RDR data read and RDRF
flag cleared to 0 in RXI
interrupt processing routine
RXI interrupt
request
generated
Figure 13.8 Example of SCI Operation for Reception
(Example with 8-Bit Data, Parity, One Stop Bit)
Summary of Contents for H8SX/1650
Page 2: ...Rev 2 00 Jun 28 2007 Page ii of xxii...
Page 106: ...Section 4 Exception Handling Rev 2 00 Jun 28 2007 Page 84 of 666 REJ09B0311 0200...
Page 142: ...Section 5 Interrupt Controller Rev 2 00 Jun 28 2007 Page 120 of 666 REJ09B0311 0200...
Page 326: ...Section 8 I O Ports Rev 2 00 Jun 28 2007 Page 304 of 666 REJ09B0311 0200...
Page 470: ...Section 12 Watchdog Timer WDT Rev 2 00 Jun 28 2007 Page 448 of 666 REJ09B0311 0200...
Page 566: ...Section 14 A D Converter Rev 2 00 Jun 28 2007 Page 544 of 666 REJ09B0311 0200...
Page 574: ...Section 16 RAM Rev 2 00 Jun 28 2007 Page 552 of 666 REJ09B0311 0200...
Page 584: ...Section 17 Clock Pulse Generator Rev 2 00 Jun 28 2007 Page 562 of 666 REJ09B0311 0200...
Page 638: ...Section 19 List of Registers Rev 2 00 Jun 28 2007 Page 616 of 666 REJ09B0311 0200...
Page 668: ...Section 20 Electrical Characteristics Rev 2 00 Jun 28 2007 Page 646 of 666 REJ09B0311 0200...
Page 676: ...Appendix Rev 2 00 Jun 28 2007 Page 654 of 666 REJ09B0311 0200...
Page 688: ...Rev 2 00 Jun 28 2007 Page 666 of 666 REJ09B0311 0200...
Page 691: ......
Page 692: ...H8SX 1650 Group Hardware Manual...