Chapter 5: Using the Command Line Interface
389
Setting IPv4 Static Routes
If the IPv4 network mode is set to static IP and your local network
contains two subnets, you can configure static routes to enable or
disable communications between the BCM2 and devices in the other
subnet.
These commands are prefixed with
network ipv4 staticRoutes.
Depending on whether the other network is directly reachable or not,
there are two methods for adding a static route. For further information,
see
Static Route Examples
(on page 178).
Method 1: add a static route when the other network is NOT
directly reachable:
config:#
network ipv4 staticRoutes add <dest-1> <hop>
Method 2: add a static route when the other network is directly
reachable:
config:#
network ipv4 staticRoutes add <dest-1> interface <ETH>
Delete an existing static route:
config:#
network ipv4 staticRoutes delete <route_ID>
Modify an existing static route:
config:#
network ipv4 staticRoutes modify <route_ID> <dest-2> <hop>
-- OR --
Summary of Contents for PMC-1000
Page 3: ...BCM2 Series Power Meter Xerus Firmware v3 4 0 User Guide...
Page 23: ...Chapter 1 Installation and Initial Configuration 11 Panel Wiring Example...
Page 54: ...Chapter 1 Installation and Initial Configuration 42 Branch Circuit Details...
Page 76: ...Chapter 2 Connecting External Equipment Optional 64...
Page 123: ...Chapter 3 Using the Web Interface 111...
Page 558: ...Appendix D RADIUS Configuration Illustration 546 Note If your BCM2 uses PAP then select PAP...
Page 563: ...Appendix D RADIUS Configuration Illustration 551 14 The new attribute is added Click OK...
Page 564: ...Appendix D RADIUS Configuration Illustration 552 15 Click Next to continue...
Page 594: ...Appendix E Additional BCM2 Information 582...
Page 612: ......