6100-Gfast Multifunction Network Analyzer Operation Manual
46
© 2020 Radiodetection Ltd
FED Type
is enabled when
FED
is set to
Auto
or
Manual
. If
Auto
is selected, you can choose
between
TS125
or
UFED IIB
.
When UFED support is enabled:
o
the
Isolation
test voltage source will
automatically be limited to 125 V,
Return Loss
test termination to 120 Ω,
and
VF/WB Impulse Noise
tests
duration to 15 min only.
o
MMT (maximum measurement time) is
determined for every test.
For tests, which run in
Continuous
mode, the MMT is set to 20 s allowing
you to observe continuous results in
numerical or graphical format. At the
end of the MMT, the continuous test is
terminated. However, due to UFED
limitation, the
Continuous Isolation
resistance test will act the same as the
test in
Snapshot
mode and terminate
after the
Soak Time
period expires.
If
Manual
is selected, the
FED Type
is set to
TS125
by default. When
FED
is
Manual
, you
can set the FED to a desired state
independently from the one defined currently in
the FED setup for a particular test. This state
will be kept indefinitely until you set the FED to
another one, change the mode to Auto, or
disable the FED.
The
Manual
state of the FED Control is not
saved in the profile and is only kept for the time
of the current session. If you leave the copper
application, at next startup FED will be set to
the value saved in the profile:
Disabled
or
Auto
.
Manual Setup
includes 5 options:
o
Open 0
o
T-R/A-B Shorted 1
o
T-R-G/A-B-E Shorted 2
o
Pass Through/Exchange Connect 3
(default)
o
ID Tone 4
Set FED
button activates the state defined in
the
Manual Setup
control.
Test Status
displays a communication with
FED status message.
FED Factory Default
button allows you to
restore the factory defaults for the following:
o
Single Test defaults
sets the default
FED state values for all the individual
tests, except
Auto Test
.
o
User Auto Test defaults
sets the
default FED state values for
Auto
Test
.
o
All these options
sets the default FED
state values for all tests.
FED States
are displayed in the
Current Test
line as a
numeral on the right-hand side of the FED icon, for
example
. Numerals match the following states:
0 = Open
1 = T-R/A-B Shorted
2 = T-R-G/A-B-E Shorted
3 = Pass Through/Exchange Connect
4 = ID Tone
5 = Terminated (100
Ω, 120 Ω, 135 Ω, 600 Ω)
Note: A line termination of 150 Ω is not supported by
the FED.
6 = Crosstalk NEXT
7 = Transmit
8 = None
Note: For all
FED States
other than
Pass
Through/Exchange Connect
, the
Dialer
tab is
disabled. If the dialer is already running before
the test starts, the dialer will be stopped on entry
of the test with a message saying
Dialer cannot
be used, hence dialer will be stopped.
- similar
to FaultMapper test.