6100-Gfast Multifunction Network Analyzer Operation Manual
60
© 2020 Radiodetection Ltd
Termination Resistance
is a read-only value
of
430 Ω
that defines how much resistance the
tester uses to connect to the line.
Threshold Settings
button opens a new page
that allows you to set the AC/DC current
thresholds for each pair.
Result
displays a snapshot of the pass/fail
status, DC current, AC current and frequency
(Hz) results for each selected wire pair.
Test Status
displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options.
4. Press
to confirm the value.
Current Thresholds
The
AC/DC Current Threshold Settings
page allows
you to set the
Current
threshold for each pair. The
threshold is a programmable value you can use as an
on-screen indicator in each test when a measured
value is too high or too low.
Type
is the threshold limit for each pair: either
Maximum
or
Minimum
.
Enabled
is a flag to use the current threshold:
either
Yes
or
No
.
To set threshold values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.
Continuous AC Page
The
Continuous AC
function measures each pair,
displaying and updating results in real time, until you
stop the test. The last valid results then remain
displayed. The
Current
test defaults to the
Continuous DC
page from the
Multimeter
menu.
Continuous AC
and
Continuous DC
are run
synchronously. Press Start/Stop on the keypad to run
the test.
Current Group
is the current test group name,
for example
Multimeter
.
Current Test
displays the test being
measured. Here you can switch to another test
from the given list. However, this action will
terminate the ongoing measurement test.