6100-Gfast Multifunction Copper Tester Operation Manual
© 2020 Radiodetection Ltd
113
Single Frequency Result Details
The
Results Details
read-only page displays the
pass/fail status,
Return Loss
and
Frequency (TX)
values.
Sweep
The
Sweep
test allows you to configure parameters
and provides a snapshot measurement of
Return Loss
in a graphical format, and pass/fail status.
Current Group
is the current test group name,
for example
Frequency Tests
.
Current Test
displays the test being
measured. Here you can switch to another
Frequency test from the given list. However,
this action will terminate the ongoing
measurement test.
Bandwidth
allows you to select the frequency
range for the test from a list of available
bandwidths:
ISDN, HDSL, SHDSL, ADSL1/2,
or
ADSL2+
.
Termination Resistance
lists a choice of
resistance values for the termination of the
signal.
Threshold Settings
button opens a new page
that allows you to set
Return Loss
thresholds
for the transmission.
Select Graph
button changes to
Graph
Selected
when pressed and opens a new
selection of function keys which allow you to
maneuver the graph as follows:
o
Cursor
- press the left/right arrow keys
to decrease/increase the values by
moving the cursor. Press and hold the
left/right arrow keys to accelerate the
cursor. Press
to recall the cursor
and place it in the middle of the current
x-axis limits.
o
Zoom
references the middle of the x/y
axis and not the cursor position. Press
the arrow keys as follows:
Right = x-axis zoom in.
Left = x-axis zoom out.
Up = y-axis zoom in.
Down = y-axis zoom out.
o
Pan
- use left/right arrow keys to pan
the x-axis and the up/down arrow keys
to pan the y-axis.
o
1:1
resets the x-axis and y-axis limits
to full scale.
o
Return To Test
removes these
function keys and displays the
Detection
page.
Result
displays the pass/fail status and a
graph of the
Return Loss Sweep
compared to
Marginal
results. If the measurement is
greater/less than the marginal test threshold,
represented by a horizontal red line, the status
is fail. Otherwise, the status is pass.
Test Status
displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR