6100-Gfast Multifunction Network Analyzer Operation Manual
44
© 2020 Radiodetection Ltd
Buzzer Threshold Voltage
allows you to
configure the hazardous voltage level from 70
to 150 volts.
Hush Time
allows you to configure the hush
timeout from 1 to 15 minutes.
Hush Buzzer
button mutes the sounding
buzzer.
Note: When the 6100-Gfast raises the hazardous
voltage flag, it opens the relays and you will have
to press Start/Stop on the keypad to re initialize
the unit. If the voltage is still too high, the 6100-
Gfast will open the relays once again preventing
any damage to the equipment. If not, the test will
start normally.
To set the buzzer settings:
1. Use the up/down arrow keys to select the
desired parameter.
2. Press
on an entry to open the
alphanumeric editor screen and use the
navigation keys to scroll through.
3. Press
to confirm each value.
7.8 Test Lead Compensation
Test Lead Compensation
should be performed when
copper test accuracy is in question, since test lead
characteristics have some impact on copper test results
(mainly resistance, capacitance, and TDR tests). Test
lead characteristics vary with respect to cable
temperature.
Refer to
connect the leads before starting compensation.
The
Test Lead Compensation
routine also performs
resistance and capacitance compensation. The page
displays the
Pass/Fail
status of the last compensation
done.
Note: Always perform a test lead compensation if the
test leads have recently been removed or
replaced.
Date and Time
identifies when the last
compensation was done or application
installation time.
Start Compensation
button allows you to start
the
Test Lead Compensation
by overwriting
the current test lead characteristics.
To perform a test lead compensation:
1. Connect the cables to the unit, leave all test
leads open, and press
to start
compensation.
2. Follow the on-screen dialogue boxes for next
steps.
7.9 FED Control
FED Control
is an option-enabled feature that tells the
test set to detect and control the Teletech TS125 or
Viavi UltraFED
™ IIB remote FED (far end device)
during testing.
Pair Detective
,
Auto Test
and many