6100-Gfast Multifunction Network Analyzer Operation Manual
40
© 2020 Radiodetection Ltd
General
The
General
tab allows you to configure the unit with
specific measurement values and graph viewing
settings.
Each parameter is described below:
Cable Temperature
specifies the temperature
of the cable under test in either
⁰
F (Fahrenheit)
or
⁰
C (Celsius) units.
Capacitance Measurement
is either
3
Terminal
or
2 Terminal
. The latter method
measures the capacitance across the 2
terminals specified (either T-R, T-G, R-G or A-
B, A-E, B-E), whereas the
3 Terminal
method
measures the capacitance across the 2
terminals specified, and shorts the remaining
(or unspecified) terminal to G/E. The
3
Terminal
method is more common and is the
default. Continue to use it unless you know you
need the
2 Terminal
method.
Note: In order to correctly determine cable length by
using the
Capacitance Measurement
, the
Cable Book
must contain both 3/2 Terminal
values.
Note: The accuracy of the
2 Terminal Capacitance
Measurement
is impacted by the use of the
FED, and the
3 Terminal
method is
recommended to be used instead.
VOP Compensation
offsets length calculation
inaccuracy caused by the changes in velocity
of the pulse propagation, depending on the
pulse width and cable length produced by skin
effect; and is applied to
TDR
,
WB Attenuation
,
and
FaultMapper
tests.
Test Startup Mode
lists the test startup type:
o
Auto
(default) automatically starts a
test when you select the respective
icon from the test sub-menu pane and
press
.
o
Manual
requires that you press
Start/Stop on the 6100-Gfast keypad to
start a test.
Report File Storage Location
is
USB
, which
is automatically selected.
Report Format
is
HTML
,
MHTML
, or
XML
as
the generated report format.
Prompt To Save Results
allows you to
Enable/Disable popup confirmation messages
before leaving a test and not saving results.
Result File Storage Location
allows you to
select where to save your results: to a
USB
or
the internal memory of the 6100-Gfast.
Landscape Mode Settings
:
o
Default Graph Mode
sets the default
graph viewing mode to either
Portrait
or
Landscape
.
o
Screen Rotation
sets your preferred
default rotation of the unit for viewing
graphs in Landscape mode. Select
either
Right
to rotate the 6100-Gfast
90 degrees clockwise so that the
keypad is on the left-hand side, or
Left
to rotate the unit 90 degrees counter-
clockwise so that the keypad is on the
right-hand side.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.