Cable Type
displays the ID, Cable Name and
Fill, (with its associated parameters) from the
current Cable Book, used for testing.
Cable Gauge
identifies the gauge system for
measuring wire sizes, in AWG (American Wire
Gauge) units or mm (metric wire size).
Cable Fill
is the type of material the cable is
filled with:
Aircore, Jelly, Pulp, 5 PR
, or
2 PR
.
Capacitance T-R/A-B
is the value for the
capacitance per length constant.
Capacitance T/R to GND/A/B to E
is the value
for the capacitance per length to ground
constant.
Attenuation @ 300 kHz
is the value for the
reduction in signal strength or insertion loss of
the cable.
Velocity of Propagation
is the velocity of
propagation for the cable.
Resistance
is the value for the resistance
constant of the cable.
Cable Length
is the length of the cable set to
provide more accurate results.
Cable Temperature
is the temperature of the
cable under test in either
°F
or
°C
.
FaultMapper Profile Details
The
Profile Details
page displays read-only
FaultMapper
Test Parameters
.
Profile Name
is the file name of the selected
saved results.
Test Identification
is the test type of the
group, for example
FaultMapper
.