6100-Gfast Multifunction Network Analyzer Operation Manual
122
© 2020 Radiodetection Ltd
3. Press
on a value to open a list box of
options and use the navigation keys to scroll
through.
4. Press
to confirm the value.
Multiple Tone Graph Result Details
The
Result Details
read-only page displays the RX
VF/WB Loss and Frequency results in graphical format
for the
Multiple RX Tone with FED
test.
Test Group
is the overall test group of the
selected saved results file, for example
Frequency Tests
.
Test Identification
is the test type of the
group, for example
RX Tone with FED
.
Test Modes
is the mode of test, for example
Multiple Tone
.
Select Graph
button changes to
Graph
Selected
when pressed and opens a new
selection of function keys which allow you to
maneuver the graph as follows:
o
Cursor
- press the left/right arrow keys
to decrease/increase the values by
moving the cursor. Press and hold the
left/right arrow keys to accelerate the
cursor. Press
to recall the cursor
and place it in the middle of the current
x-axis limits.
o
Zoom
references the middle of the x/y
axis and not the cursor position. Press
the arrow keys as follows:
Right = x-axis zoom in.
Left = x-axis zoom out.
Up = y-axis zoom in.
Down = y-axis zoom out.
Pan
- use left/right arrow keys to pan the x-axis
and the up/down arrow keys to pan the y-axis.
1:1
resets the x-axis and y-axis limits to full
scale.
Return To Test
removes these function keys
and returns to the test results page.
Multiple Tone Table
The
Multiple Tone Table
displays the
RX
Frequency/Loss
for the
FED Frequency Group
selected.
for
VF Receive Tone
:
o
POTS/PSTN: 404, 804, 1004, 1204,
1804, 2204, 2404, 2804, 3204, 3404
Hz
o
VF 5 Tone: 404, 1004, 2804, 3004,
3604 Hz
for
WB Receive Tone
:
o
HDSL: 20, 30, 50, 70, 90, 110, 130,
196, 400 kHz
o
T1/E1: 200, 400, 500, 700, 772, 1024
kHz
o
ADSL1/2+: 25, 69, 90, 110, 138, 300,
550, 800, 1104, 2208 kHz
o
VDSL2-12: 25, 138, 276, 3000, 3750,
5200, 8500, 12000 kHz
o
WB 5 Tone: 196, 392, 772, 1100, 2200
kHz