6100-Gfast Multifunction Copper Tester Operation Manual
© 2020 Radiodetection Ltd
139
14.4 RFL Cable Setup
The
Cable Setup
page allows you to set cable
parameters for an RFL test. Settings are shared by
Single Pair, Separate Good Pair,
and
K-Test
.
Changes done in Cable Setup for one test are reflected
in all.
No. of Cable Sections
allows you to set the
number of consecutive cable sections, to a
maximum of 5. If unknown, set the number to
1.
Cable Type #
displays the number of a cable
section set above, ID, Cable Name and Fill,
and allows you to select an entry (with its
associated parameters) from the current Cable
Book, to use for testing. The selection is not
saved when leaving the test. The current Cable
Book entry is shown by default.
Resistance
specifies a value for the resistance
constant of the cable in each section.
Section Length
allows you to specify the cable
length of each section. If the cable length is
unknown, specify 0 and the RFL test will
measure the length.
Load Coil
allows you to set the detection of the
presence of load coils to either
Yes
or
No
.
Cable Temperature
allows you to change the
temperature of the cable under test in either
°F
or
°C
.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press on a value to open a list box of options
or the alphanumeric editor screen and use the
navigation keys to scroll through.
4. Press
to confirm the value.
14.5 Result Manager
RFL Summary
The results
Summary
page displays
Fault Status
,
general and identification information, along with
comments, for the test.
Test Modes
lists the RFL tests saved into the
results file.
Fault Status
displays the status for each mode
that was run.
General Information
displays read-only
information pertaining to the test result.
o
Result File Name
o
Test Date and Time
o
Test Identification
o
Test Modes
Test Lead Compensation
displays read-only
Date and Time
and
Pass/Fail Status
of the
compensated resistance and capacitance
based on the cable temperature of the test
lead.
Editable Identification Fields
display values
from the loaded file. You can edit all fields
using the editor screen or by selecting an entry
from the list box.