6100-Gfast Multifunction Copper Tester Operation Manual
© 2020 Radiodetection Ltd
63
Result
displays a snapshot of the pass/fail
status,
Resistance
and
Length
for each
selected wire pair.
Test Status
displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options.
4. Press
to confirm the value.
Resistance Thresholds
The
Resistance Threshold Settings
page allows you
to set the
Resistance
for each pair. The threshold is a
programmable value you can use as an on-screen
indicator in each test when a measured value is too
high or too low.
Type
is the threshold limit for each pair: either
Maximum
or
Minimum
.
Enabled
is a flag to use the current threshold:
either
Yes
or
No
.
To set threshold values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.
Continuous
The
Continuous
function measures each pair,
displaying and updating results in
real time
, until you
stop the test. The last valid results then remain
displayed. In
Continuous
mode, significant changes or
fluctuations in the values can indicate wet faults or
intermittent metallic faults (
swinging
faults), or other
foreign voltages on the pair. (Sometimes ground
signals can influence a pair through a ground fault.)
Current Group
is the current test group name,
for example
Multimeter
.
Current Test
displays the test being
measured. When FED is
Enabled
, the FED
icon and numeric state are displayed beside
the
Current Test
.
Here you can switch to another test from the
given list. However, this action will terminate
the ongoing measurement test.
Selected Pair
allows you to select
All Pairs
or
a single wire pair for measurement.
Cable Parameters
:
o
Cable Type
displays the ID, Cable
Name and Fill, and allows you to select