6100-Gfast Multifunction Network Analyzer Operation Manual
152
© 2020 Radiodetection Ltd
on page
147
,
on page
147
,
on page
148
,
on page
148
, and
for more information.
Summary
The
Result Details Summary
page displays the
overall pass/fail status of all tests selected for auto
testing. This page varies slightly from the run
User
Auto Test
page in that there are no configurable
parameters.
Test Group
is the overall test group of the
selected saved results file, for example
Auto
Test
.
Test Identification
is the test type of the
group, for example
User Auto Test
.
Cable Setup
button opens a new page that
allows you to view the parameters of the cable
used in the Auto Test. Press to open the
page.
Cable Setup
The
Cable Setup
page displays read-only parameters
of the cable used in the
Auto Test
.
Cable Type
displays the ID, Cable Name and
Fill, (with its associated parameters) from the
current Cable Book, used for testing.
Cable Fill Material
is the type of material the
cable is filled with:
Aircore, Jelly, Pulp, 5 PR
,
or
2 PR
.
Velocity of Propagation
is the velocity of
propagation for the cable.
Cable Temperature
is the temperature of the
cable under test in either
°F
or
°C
.
15.5 Profile Details
Profile Details
contains the details of the
Test
Selection
settings for
User Auto Test
. If FED is
Enabled
on
FED Setup
page,
Pause
is replaced by
FED States
parameters and will show the FED state
for each test.
Test Parameters
button opens a new page
displaying read-only parameter details of all
tests.
Test Thresholds
button opens new pages
displaying read-only threshold values for all
tests.