6100-Gfast Multifunction Copper Tester Operation Manual
© 2020 Radiodetection Ltd
37
VOP V/2 m/µs
is the velocity of propagation for
the cable in m/µs divided by 2
Temperature
specifies the temperature of
reference at which all cable parameters have
been measured, in either
⁰
F (Fahrenheit) or
⁰
C
(Celsius) units. The measurement units are
updated based on the
Temperature
settings in
Setup/Application Settings/Standard
.
To view and modify the cable details:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options and use the navigation keys to scroll
through.
4. Press
to confirm the value.
5. Press the
Accept
function key to update the
cable details with your changes.
Add Cable
The
Add Cable
page allows you to add a new cable
entry into the
CableBookSettings
using the following
parameters for the currently highlighted
Cable ID
.
Cable ID
displays the cable ID number. This
parameter that cannot be modified.
Cable Name
is the name of the cable in the
Cable Book
.
Cable Gauge
is the gauge system for
measuring wire sizes in AWG (American Wire
Gauge0 units or mm (metric wire size).
Cable Fill
allows you to select the type of
material the cable can be filled with:
Aircore
,
Jelly
,
Pulp 5
,
PR
, or
2 PR
.
Capacitance T-R/A-B
allows you to specify a
value for the capacitance per length constant.
Capacitance T/R to GND/A/B to E
allows you
to specify a value for the capacitance per
length to ground constant.
Resistance
allows you specify a value for the
resistance constant of the cable.
Attenuation @ 300 kHz
allows you to specify
a value for the reduction in signal strength or
insertion loss of the cable.
VOP
allows you to set the velocity of
propagation for the cable.
Temperature
specifies the temperature of
reference at which all cable parameters have
been measured.
Add
function key adds the new cable entry to
the
Cable Book
.
To add a new cable entry:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.
5. Press the
Add
function key to append the new
cable entry to the end of the
CableBookSettings
. If the maximum number
of Cable Book entries has been reached,
delete an entry before adding a new one.