282
Chapter
5
Mounting
F3SG-SR
User’s Manual
Wiring and Installation
4.
Fully loosen the Mounting Screw (hexagon socket head cap screw (M4×22)) of the Side-Mount
Bracket. (Fig. 4) Then slide the hooks of the Brackets (1) and (2) in the groove of the backside of the
sensor housing. (Fig. 5)
5.
Securely tighten the Mounting Screw to fix the Side-Mount Bracket to the sensor housing. The
recommended torque to tighten the Mounting Screw of the Side-Mount Bracket is 3.0 N•m. (Fig. 6)
Tightening screws with a torque that considerably exceeds the recommended torque may cause failure.
Fig. 4
Fig. 5
Mounting Screw
(hexagon socket head
cap screw (M4×22))
Fit the hooks of Side-Mount
Brackets to the groove of the
backside of the housing
Loosen
Bracket (1)
Bracket (2)
Hook
Mounting Screw
Securely tighten
Fig. 6
Mounting Screw