114
Chapter
2
Area Beam Indicator (ABI)
F3SG-SR
User’s Manual
System Operation and Functions
monitoring beams). One or two beams are selected automatically from the group as monitoring
beams.
When all monitoring beams reach stable state, all the the ABI indicators change indication at every
second like green -> orange -> green -> orange -> green, indicating that beam adjustment is
completed.
This operation is executed only in the unblocked/blocked state indication configuration and during start-up. In addition, if
stable state of all monitoring beams can be confirmed soon after synchronization is established, this indication is not
executed. So, after installation is completed, when the F3SG-SR is powered up again in the arrangement and usage that
all beams are unblocked or in the normal blocked state, the indication above is not executed.
Input Signal Linkage
Indication of all the ABI indicators can be operated by muting input A and muting input B. For example,
by turning ON the ABI indicators using the output signal from the PLC, the ABI indicators are usable as
a guide light for the operator or a muting lamp.
Output Information
F3SG-SR’s state can be displayed by the ABI indicators.
The information assigned is equal to the information assigned to the auxiliary output.
For the details of the information assigned to the auxiliary output, refer to 2-12. Auxiliary Output.
2-22-2. Factory Default Setting
The factory default setting is set as unblocked/blocked state information.
2-22-3. Setting Change using Intelligent Tap
It is unable to change the setting of this function using the DIP Switch of the Intelligent Tap.
2-22-4. Setting Change using SD Manager 3
The following setting can be done using SD Manager 3.
Unblocked/blocked state of monitoring beam
ABI indicator state
Stable state
Illuminated in orange
Unstable state or blocked
Illuminated in red
Muting input A
Muting input B
ABI indicator state
0 V to 1/2 Vs
0 V to 1/2 Vs
OFF
Vs-3 V to Vs
0 V to 1/2 Vs
Illuminated in green
0 V to 1/2 Vs
Vs-3 V to Vs
Illuminated in red
Vs-3 V to Vs
Vs-3 V to Vs
Illuminated in orange
Function name
Initial value
Configurable value or numerical range
Output operation mode
Unblocking/blocking
information
Disabled, unblocking/blocking information, input signal
linkage*1, and output information
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...