206
Chapter
4
Changing Settings with SD Manager 3
F3SG-SR
User’s Manual
Setting with SD Manager 3
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor]
button.
Floating Blanking Setup Procedure
1.
Enable the Floating Blanking function (No. 1).
2.
Set up the Floating Blanking function (No. 3).
3.
Set up the number of floating beams (No. 3).
4.
Set up the number of allowable beams (No. 3).
5.
Set up the Temporarily Disable Monitoring function (No. 4).
When Enable is selected, also set up the monitoring-temporarily-disabled time limit (No. 4).
This function is only available when [Lockout] or [Cancel blanking zone] option is selected for the Floating Blanking
Monitoring function.
6.
Click the [Write configuration] button. On the settings list which will appear, confirm that the changed
settings are correct, and click the [OK] button.
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...