307
F3SG-SR
User’s Manual
Chapter
5
Wiring
Wiring and Installation
E
5-4-4. Functional Earth Connection
The F3SG-SR operates properly without functional earth connection in a general industrial
environment. If the F3SG-SR fails due to electrical noise, connecting the F3SG-SR to the functional
earth may work to prevent the noise. It is recommended the functional earth terminal of the F3SG-SR
be connected to functional earth cables. Connection with protective earth cables may cause the F3SG-
SR to fail due to a noise level of the environment.
When you connect the F3SG-SR with the functional earth, connect an earth cable to the functional
earth terminals, as shown below.
The size of the screws of the terminals is M3. Make sure to use crimp terminals that fits the size.
The earth cable must have a cross section of 1 mm
2
or more with conductor resistance of 0.058 ohms/
m or less and a length of 20 m or less.
F3SG-SR root cable entry *1
Root cable
Functional earth terminal (M3)
Connect an earth cable to either of these screws. *2 *3
Do not loosen these screws.
*1. Select either of the terminals of the emitter and receiver according
to your environment.
*2. The color of functional earth terminal screws is silver for the emitter
and black for the receiver.
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...