319
F3SG-SR
User’s Manual
Chapter
6
Wiring Exa
m
p
le
s
(f
or F3
SG-SR)
Input/Output Circuit and Applications
E
6-2-1-4. Manual Reset Mode with EDM
[Wiring Example]
When a functional earth is necessary, wire an earth cable according to the example in
Optical Synchronization and EDM Unused
. Also refer to
5-4-4. Functional Earth Connection
for more information.
KM1
KM2
M
F39-JG
C-L
F39-JG
C-D
Timing chart
24 VDC
Wiring for NPN *1
*3
24 VDC
KM1
KM2
S2
S1
KM1
KM2
S1: Test switch
S2: Lockout/interlock reset switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor
M: Motor
Beam state: Unblocked
Blocked
Test switch (S1)
Reset switch (S2)
OSSD
Receiver
Emitter
OSSD 1 (Black)
OSSD 2 (White)
24V/0V (Brown)
OPERATING RANGE
SELECT INPUT (Yellow) *2
TEST (Black)
Not used (White)
24V/0V (Brown)
0V/24V (Blue)
0V/24V (Blue)
AUX (Red)
MUTE B (Pink)
MUTE A (Gray)
RESET/EDM
(Yellow)
*1. Reverse the polarity of the power supply when using in the NPN system.
*2. Connect the line to 0 VDC if Operating Range Selection is used in Short Mode.
*3. This is the case for a PELV circuit.
*4. Set the function with the DIP Switches on the Intelligent Tap or the SD Manager
3, restore the settings to the F3SG-SR, and perform wiring according to the
wiring diagram.
*5. This wiring example shows light emission stop when connected to 24 VDC with
PNP setting, and light emission stop when connected to 0 VDC with NPN
setting. If TEST switch is not needed, refer to
: Indicates a switch position.
Function
Setting
DIP switch
SD Manager 3
EDM *4
EDM Enabled
[External device monitoring] : Enable
Interlock *4
Manual Reset
[Start interlock] : Enable
[Restart interlock] : Enable
Operating Range Selection
Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.
Long *4
[Operating Range Selection] : Long mode *4
Non-Muting system
Perform wiring according to the wiring diagram.
N/A
[Muting] : Disable *4
External Test used
Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact). *5
N/A
[External test signal inversion] : Disable
Optical Synchronization
Do not connect the COM(+) and COM(-) lines of the of emitter and receiver with each other.
㻟
㻻㻺
㻠
㻻㻺
㻡
㻻㻺
㻤
㻻㻺
Intelligent Tap
Needed
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...