User’s Manual
Input/Output Circuit and Applications
6-2-1-7. Manual Reset Mode with Reset Switch Connector
[Wiring Example]
• When using the Reset Switch Connector (F39-GCNY3), the following functions are not available.
- External Device Monitoring (EDM)
• When a functional earth is necessary, wire an earth cable according to the example in
Optical Synchronization and EDM Unused
. Also refer to
5-4-4. Functional Earth Connection
for more information.
S2
S1
24 VDC
24 VDC
F39-JG
C-L
F39-GCNY3
F39-JGR3K-D
XS5F-D421
80-F
F39-JG
A-D
IN1
IN2
L1
Wiring for NPN *1
OSSD 1 (Black)
OSSD 2 (White)
24V/0V (Brown)
TEST (Black)
Not used (White)
24V/0V (Brown)
0V/24V (Blue)
0V/24V (Blue)
AUX (Red)
MUTE B (Pink)
MUTE A (Gray)
RESET (Yellow)
0V/24V (Blue)
RESET (White)
24V/0V (Brown)
AUX (Black)
OPERATING
RANGE SELECT
INPUT (Yellow) *2
Emitter
Receiver
Safety controller
*3 *4
*5
Timing chart
Beam state: Unblocked
Blocked
Reset switch (S2)
Test switch (S1)
OSSD
S1: Test switch
S2: Lockout/interlock reset switch
L1: Lamp
: Indicates a switch position.
Function
Setting
DIP switch
SD Manager 3
EDM
EDM Disabled (factory default setting)
Interlock *6
Manual Reset
[Start interlock] : Enable
[Restart interlock] : Enable
Operating Range Selection
Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.
Long *6
[Operating Range Selection] : Long mode *6
Non-Muting system
Perform wiring according to the wiring diagram.
N/A
[Muting] : Disable *6
External Test used
Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact).
*
7
N/A
[External test signal inversion] : Disable
Optical Synchronization
Open the COM(+) and COM(-) lines of the emitter.
㻠
㻻㻺
㻡
㻻㻺
㻤
㻻㻺
*1. Reverse the polarity of the power supply when using in the NPN system.
Select a safety controller of PNP or NPN type according to the system of
your application.
*2. Connect the line to 0 VDC if Operating Range Selection is used in Short
Mode.
6-3. Connectable Safety Control Units
for more information.
*4. The safety controller and the F3SG-SR must share the power supply or be
connected to the common terminal of the power supply.
*5. This is the case for a PELV circuit.
*6. Set the function with the DIP Switches on the Intelligent Tap or the SD
Manager 3, restore the settings to the F3SG-SR, and perform wiring
according to the wiring diagram.
*7. This wiring example shows light emission stop when connected to 24 VDC
with PNP setting, and light emission stop when connected to 0 VDC with
NPN setting. If TEST switch is not needed, refer to
Intelligent Tap
Needed
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...